After having removed the electronic control panel, work on the electronic circuit board trimmer "3"
with a small size screw driver.
7. DISPLAY CASE SET-UP
7.1
First Start-up
Before making the display case working, we recommend to clean it using a neutral soap and non-
abrasive sponges, then wipe it away.
Warning: the cabinet is set at 4°C. If a different temperature is required, see chapter 10.
The frequency and the duration of the defrosting operation are regulated in conformity with
the standard environmental values (25 Deg C/60% R.H.). If the environmental conditions
should be unfavourable, we recommend to increase both the number and the duration of the
defrosting operations.
7.2
Product loading
WARNING: BEFORE PLACING THE GOODS INTO THE DISPLAY CASE, ENSURE
THAT THEY HAVE THE SAME TEMPERATURE OF THE CABINETS.
Do not fill the cabinet over the max load line on the side glass.
The products placet over the max load line, cannot be properly cooled.
Do not pile the displayed goods but leave proper spaces for the refrigerated air circulation.
7.3
Periodical checks
For the good maintenance of the exposed goods, check every day the inner temperature of the
display cabinet.
In display cabinets with motor incorporated in heavy environment conditions, the production of
condensing water can become excessive even for the automatic evaporation system; in these
conditions it is advised to carry out the emptying operation by hand (see chapter 8.1).
20