A suitable omni-polar switch shall be installed and sized according to the actual absorption, in order
to guarantee completely the disconnection, from the power network. A fuse protection system with
the characteristics shown on the data-plate shall be installed (or equivalent system).
This switch must be incorporated in the supply network, dedicated only and exclusively to this circuit
and installed in the immediate vicinity.
The machine has to be absolutely turned off by this switch: only this switch gives the full warranty
of complete detachment from the electric network.
Make sure the appliance is linked to an effi cient ground connection.
WARNING:
and that not too many units are connected to it. An undersized or poor "ground connection" might lead to
corrosion and/or pitting eff ect on the stainless steel plates, even to perforation.
The machine has a terminal on the back panel indicated by the symbol
diff erent appliances, to prevent electro-static shocks.
Note:
Do not modify the protections or remove them. Only if the power supply is cut off from the main switch on the wall.
Only if the power supply is cut off from the main switch on the wall it is possible to work on the dishwasher electric circuits.
Lock the main switch on the wall to signal the work in progress on the dishwasher's electric circuits.

1.5 Draining system

The draining system has to be installed considering the draining points and the data provided on the machine layout.
Maximum height for draining is 6" (cm 15).
Minimum capacity 1.32 gps (5 l/s).

1.6 Ventilation

Use extractor fans to guarantee a minimum ventilation of 300 CFM (500m3/h).
It is suggested to position the extractor fans close to the machine entry. The exhaust air shall not be vented into a wall, a
ceiling or a concealed space of the building.

1.7 Detergent dispenser connection

FRONT
TANK VIEW
holes for detergent dispenser probes
check very carefully if the "ground connection" of the machine is properly sized and fully effi cient,
350mm 13 ¾ in
that is meant to link the metal structures of
SIDE
TANK VIEW
USA
DANGER!
detergent
injection hole
50 mm 2 in
page 39