1.3 Water connections

Water connections must be carried out in compliance with current local standards.
The Water system must have characteristics between the parameters specifi ed in table 1.

Water supply characteristics

Static Pressure*
Dynamic Pressure
Cold water-supply temperature (machine with extra power)
Hot water-supply temperature
table 1
Capacity
*If higher than 87PSI (600 kPa),
To improve the machine performance keep the temperature intervals indicated.
It has to be installed a water supply shut-off valve close to the machine in an accessible point.
Use only new fl exible pipes for the water connections.
1.3.1 Water supply characteristics
The water supply must be potable.
The inlet water must also meet the parameters given in the table 2.
Water parameters table
Chlorine
pH
Water hardness
Iron
Dry residue
table 2
Manganese
Out of range values might lead to corrosion and jeopardize the life of the machine.
1
2
Should the water hardness is higher it is compulsory to install a water softner and check periodically its operation.
Out of range values might lead scaling and sediments with a consequent lower performance, functionality, and expected
3
life of the machine.
Desired value: Out of range values might lead stainless steel blackening/tarnishing.
4
It is recommended a water test once a year.

1.4 Electrical connection

Only qualifi ed and properly trained personnel can operate on the electric board and connections.
Before the installation:
Make sure that the voltage is the same as reported on the data-plate.
Make sure the line voltage matches the machine power and voltage indicated on the machine data-plate (as shown on par.
1.1).
Electrical connection must be carried out in compliance with the current local standards.
Refer to the data reported on the data-plate and on the labels found on the dishwasher to check sizings and electrical
connections.
page 38
it is mandatory
1
3
3
4
to install a pressure reducer.
Min
30PSI (~ 200kPa) 87PSI (~ 600kPa)
21PSI (~ 150kPa) 60PSI (~ 400kPa)
110°F (~ 43°C)
175°F (~ 79°C)
140°F (~ 60°C)
175°F (~ 79°C)
4 gpm (~ 15 l/min)
Min
6,5
1
2°f
Max
Max
2mg/l
8,5
3
8°f
2-3
0,2 mg/l
500 mg/l
0,05 mg/l

Publicité