GENERAL INSTRUCTIONS

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,
PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48" FROM THE
SURFACES AROUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT. AVOID CONTACT
HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING GAS
LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFORE PRESSURE
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE.
USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING
COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
DO NOT USE A BLOWER INSERT, HEAT EXCHANGER INSERT OR ANY OTHER ACCESSORY NOT APPROVED FOR USE
Thoroughly clean the chimney, flue and existing
appliance before installing the new appliance into
it. Do not burn solid fuels in any appliance that is
equipped with this gas log set.
The installation of this appliance must conform with
local codes or in the absence of local codes, it must
conform to ANSI Z.223.1 or the CAN/CGA B149.
Do not operate appliance in the presence of gasoline
or other flammable liquids and vapours. Keep area
clear of other combustible materials. The appliance
and its shut off must be disconnected from the gas supply piping system before any pressure testing of the
system is done.
Installation practices vary from region to region and it is important to know the specifics that apply to your
area,
For example: in Massachusetts State:
This product must be installed by a licensed plumber or gas fitter when installed within the
commonwealth of Massachusetts.
The appliance damper must be removed or welded in the open position prior to installation of a
appliance insert or gas log.
The appliance off valve must be a "T" handle gas cock.
The flexible connector must not be longer than 36 inches.
The appliance is not approved for installation in a bedroom or bathroom unless the appliance is a
direct vent sealed combustion product.
A carbon monoxide detector is required in all rooms containing gas fired appliances.
No external electricity (110 volts or 24 volts) is required for the gas system operation.
W415-1071 / D / 08.08.16
WITH THE GLASS DOOR OPENED OR REMOVED.
PROVIDE ADEQUATE VENTILATION.
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
FRONT FACE OF THE UNIT.
WHEN THE APPLIANCE IS OPERATING.
FIRE RISK. EXPLOSION HAZARD.
TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG.
WARNING
!
WITH THIS APPLIANCE
www.n certi ed.org
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certi ed in the U.S.
by the National Fireplace
Institute ® (NFI) as NFI Gas
Specialists