4.1.2 Installation of the chamber system LW 1000
Installing gaskets/seals
B
A
D
Before installation, care must always be taken that the pressure
pipes are at a frost-free depth after installation. Depending on
the installation depth, the chamber system is set up with adap-
ters. To do this, proceed as follows:
Keep the seal groove clean. The seals are inserted as shown
in the adjacent illustrations. Please note the two different dia-
meters. Only grease the seals shortly before the chamber parts
are fitted together.
Installing access steps
The access steps are only in KESSEL chamber system 1000
included in delivery.
328-221
Installation and assembly
C
Fig. 10
Fig. 11
24 /84
Putting the chamber parts together
Set the chamber parts on top of one another. Please make sure
the access steps are arranged correctly. Put the chamber parts
together as shown in the above diagram.
Installing the vertically adjustable upper section
Fig. 12
Rubber hammer
the seal into
place (no grease)
Grease the lip
seal, insert the
attachment
piece and fix
in place using
a clamping
ring
Fine adjust-
ment can be
carried out
using adjust-
ment screws.
Fig. 14
2017/02