If the battery is in a state of extreme deep-discharge (under 2 V), a warning ap-
pears instructing the user to disconnect the battery.
Batteries in a state of extreme deep-discharge must be replaced without using
Battery changing mode.
Install and connect a new battery
6
WARNING!
Danger following ignition of oxyhydrogen caused by sparks resulting from the
charging leads being disconnected too soon.
This can result in serious injury and damage to property.
Before disconnecting the charging leads, press the Stop/Start button to fi-
nish buffering.
7
-
Disconnect the charger
8
-
Disconnect the black charging lead from the negative (-) vehicle charging
lead
-
Disconnect the red charging lead from the positive (+) vehicle charging
lead
Remember:
Start charging mode to charge the (as yet not fully charged) battery.
9
Set the correct battery voltage using the Up/Down
keys (6V / 12V / 24V).
Confirm the selection using the Stop/Start key.
To cancel Battery changing mode:
Press the Stop/Start key