5
The charger automatically recognises the battery and starts the charging process
after 5 seconds.
*)
Serious injury and material damage can result, in particular due to short circuits,
arcs and oxyhydrogen explosions.
Danger following ignition of oxyhydrogen caused by sparks resulting from the
charging leads being disconnected too soon.
This can result in serious injury and damage to property.
7
72
Connect the battery - the de-energised charging leads mean there are no
sparks when connecting to the battery, even if the charger is already connec-
ted to the mains supply.
-
Connect the red charging lead to the positive pole (+) of the battery
-
Connect the black charging lead to the negative pole (-) of the battery
WARNING!
Danger if battery is not monitored during conservation charging.
Visually inspect the battery at a regular interval as specified by the manufac-
turer (but at least once per week) to ensure the battery is filled to the max.
marking with acid.
In the event of the following, do not start the device or switch it off immedia-
tely and have the battery checked by an authorised workshop:
Uneven acid levels or high water consumption in individual cells
Impermissible warming of the battery to above 55 °C (131 °F).
WARNING!
Before disconnecting the charging leads, press the Stop/Start button to fi-
nish buffering.
6
-
Disconnect the charger
-
Disconnect the black charging lead from the negative pole (-) of the bat-
tery
-
Disconnect the red charging lead from the positive pole (+) on the batte-
ry
-
A set of four bars shows the state
of charge of the battery (e.g. three
bars represent a state of charge of
80%).
(Shown symbolically; accurate vol-
tage indicator: roughly 14-16 V)
-
All four bars are continuously dis-
played.
-
The state of charge is 100%.
-
The battery is ready to use.
-
The battery may remain connected
to the charger under certain con-
ditions
-
Conservation charging counteracts
battery self discharge.
To terminate "Refresh" charging:
Press the Stop/Start key
*)
.