Reset filter saturation
After carrying out maintenance on the filters (grease and/or
activated carbon) hold down the
"
"
the
LED turns off and the count restarts.
Activation of activated carbon odour filter saturation
indicator
This indicator is normally deactivated.
To activate it, proceed as follows:
- turn on the aspiration hob by pressing
- with the aspiration motor and cooking zones off, press and
hold
;
"
"
-
turns on, then off to indicate successful
activation.
Deactivation of activated carbon odour filter saturation
indicator
repeat the activation steps described above
"
"
flashes, then turns off to indicate successful
deactivation.
Automatic mode
The hood will turn on at the most suitable speed, adapting the
extraction capacity to the maximum cooking level used in the
cooking zone.
Once the hob is turned off, the hood adapts its aspiration
speed, gradually decreasing it, so as to eliminate residual
vapours and odours
To activate this function:
Briefly press
, the LED "
that the hood is working in this mode.
Automatic hood mode with SNAP
For information on how to make the connection between the
hood and SNAP
see the manual supplied with SNAP
®,
visit www.elica.com.
is an auxiliary extraction unit able to operate at
Note: SNAP
®
the same time as the hood.
To activate this function:
Briefly press
, the LED "
will light up to indicate that the hood is working in this mode.
The device can also be used in combination with a
Window sensor KIT (not supplied by the manufacturer).
If the Window sensor KIT is installed (only in the case of use
in EXTRACTOR mode), air extraction will halt every time the
window in the room, on which the KIT is applied, is closed.
key;
;
" (11) will light up to indicate
®
or
®
" and the LED SNAP (11)
• The KIT must be electrically connected to the device by
qualified and specialised technical personnel.
• The KIT must be certified separately in accordance with
the safety standards for the component and its use with
the device. Installation must be carried out in accordance
with current regulations for domestic systems.
PLEASE NOTE:
• the wiring of the KIT to be connected to the device must
be part of a certified safety extra-low voltage (SELV)
circuit.
• the manufacturer of this device declines all liability for
any inconvenience, damage or fires caused by defects
and/or problems associated with the malfunction and/or
incorrect installation of the KIT.
63