Troubleshooting Charger - Stihl BGA 56 Notice D'emploi

Masquer les pouces Voir aussi pour BGA 56:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

17 Troubleshooting
Condition
LEDs on Battery
Battery jams when
being inserted in
battery compartment.
Charge process does
1 LED glows red.
not start when battery
is inserted in the
charger.

17.2 Troubleshooting Charger

Condition
LED on Charger
Battery not being
LED flashes red.
charged.
BGA 56
Cause
Normal battery life has been
exceeded
Guides or contacts in battery
compartment dirty.
Battery too hot or too cold.
Cause
No electrical contact
between charger and
battery.
Malfunction in charger.
Remedy
Replace the battery.
Clean guides or contacts in battery compartment,
@ 15.1.
Leave battery in the charger.
Charge process starts automatically as soon as
permissible temperature range is reached.
Remedy
Remove the battery.
Clean contacts on charger, @ 15.3.
Fit the battery.
Contact your STIHL servicing dealer.