Appliance specification
Product name
Gas Category
Gas and Supply
Pressure
Country of
Destination
Injector Size
Gas Consumption
Warning: This appliance shall be installed in conformity with the current regulations and used
only in a well-ventilated location. Consult the instructions before installing and using
this appliance.
Burner rating of ignition pilot: 750W
Nominal Gas Consumption Table for
BURNER
GF4
GF3
Note: The pressure test point is located on the gas manifold (refer below).
TEST POINT PRESSURE
The pressure test point is located on the gas manifold and is accessed by
opening the door. The test point pressure is shown in the 'Nominal Gas
Consumption Table' above and is set with the burners operating at maximum
setting.
VENTILATION AND AIR SUPPLY
All gas burners and pilots require sufficient air to operate. For optimum
performance and for your safety, it is ESSENTIAL that the equipment, in the
installed position, has the proper air and ventilation and the correct
exhaust/canopy and air balance. The correct installation and compliance with
all regulatory and other requirements is the responsibility of the
purchaser/owner.
Please note that a strong exhaust canopy will create a vacuum if there is
insufficient replacement air. The amount of air exhausted must be replaced by
an equal amount of air.
Gas fryer Manual
WWW.HOREPA.NL
Gas Fryer
I
2H
G20 at 20 mbar
AT, BG, CR, CZ, DK,
EE, FI, GR, HR, HU, IS,
IE, IT, LV, LT, NO, PT,
RO, SK, SI, ES, SE, CH,
TR and GB
Ø 2.3 mm
34kW for GF4 ; 27KW for GF3
I
only ( reference only)
2H
Test pressure at gas inlet
20 mbar
20 mbar
Tel: +31 (0)653140903
Page 8
Type of appliances
I
I
2E
2L
G20 at 20
G25 at
mbar
25 mbar
BE, FR
NL
Ø 2.3 mm
Ø 2.2 mm
Test pressure at test point
13.5 mbar
14.7 mbar
Type A
1
I
2E+
G20/G25 at
20/25 mbar
DE, LU, PL
Ø 2.2 mm