14) PUTTING INTO OPERATION
1. ON/OFF switch set to 0, Fig. O.
2. Double-check you have set the Dip switches correctly, especially n° 1 and 5.
3. Double-check that the KEY, PHOT CLOSE and PHOT OPEN contacts are
connected properly or, if not used, are connected to COM.
4. Power up the automatic door operator
5. Set the ON/OFF switch to 1, Fig. O
6. Check that the display reads E6
7. Set the jumper so that the display is set up correctly, Fig. AD
8. If a solenoid lock is installed, set parameter 10
9. Run the Supervised sensor acquisition procedure Select LS by pressing the
[+] and [-] keys; press [ENT]. When the display reads [--], hold [ENT] down for 5
seconds to validate the command; when [--] disappears, release the [ENT] key;
confirm the sensors detected with [ENT] or press [ESC] to cancel acquisition.
10. Run the Autoset procedure; Select LP by pressing the [+] and [-] keys; press
[ENT]. When the display reads [--], hold [ENT] down for 5 seconds to
validate the command; when [--] disappears, release the [ENT] key. The door
will open and the self-learning cycle will start.
CAUTION: During opening, stop the door leaf in the position where you want
travel to end in order to determine the maximum swing. Straight afterwards, the
door will close fully and the message CL will flash on the display.
Once the door has reached the fully closed position and CL is no longer flashing,
you can test the automatic door operator's operation by pressing the [ENT] key:
the door will open and close as usual.
During normal operation, swing will be smaller than the angle detected during
the stops acquisition procedure so as to allow operation when there is no
mechanical stop.
Every time the system is switched back on (RESET operation), when the first
command is given, the automatic door operator will try to reach the fully open
position and will then close at reduced speed.
15) BRAKING LEVEL SELECTION (for VISTA SW SXL only) Fig. I
16) LOGIC SELECTION SWITCH Fig. O
In addition to managing the logic selector, you have the option of connecting a
pushbutton logic selection switch, which can be used to select the three main
logic modes:
-
Manually opened door
-
Radar in standard mode
-
Door total open
If the logic selector is fitted, operation of the pushbutton logic selection switch
is inhibited
17) INSTALLING THE BATTERIES (optional extra for VISTA SW MXL only) Fig. S
1. Fit the batteries
2. Connect the batteries to the circuit board
3. Attach the battery charger board to the circuit board
4. Set Dip Switch 7=ON and Dip Switch 6 (OFF=Continuous operation; or
ON=Panic opening).
18) SOLENOID LOCK MANAGEMENT
The system is compatible with the following solenoid lock options, which can
be chosen with parameter 10 (see the "Operating parameter management-
display" section)
Key
= HAMMER
= OPENING ACTIVATION
= DOOR OPEN BY 10°
INSTALLATION MANUAL
= DOOR ALMOST CLOSED
= DOOR CLOSED
LOCK IN PULSE MODE WITH RELOCK WHEN DOOR CLOSED AGAIN
(Parameter 10=1)
Command
t=50÷500 ms (Parameter 11)
STANDARD MAGNETIC LOCK (Parameter 10=2)
Command
t=200÷2000 ms (Parameter 11)
FAIL-SAFE LOCK (Parameter 10=3)
Command
t=200÷2000 ms (Parameter 11)
MOTORIZED LOCK (Parameter 10=4)
Command
t=500÷5000 ms (Parameter 11)
LOCK WITH RELOCK WHEN POWER IS CUT OFF (Parameter 10=5)
Command
Magnetic ( maglock) with activation delay while closing (Parameter 10=6)
Command
t=200÷2000 ms (Parameter 11)
ms
t
[
t=500÷5000 ms (Parameter 11)
ms
t
[
- 35