Diagnostics and warnings
Warnings
Steady
Door Open
OP
Flashing
Door opening
Steady
Door closed
CL
Flashing
Door closing
Steady
System parameter initialization fail (self-learning) error. Run Autoset procedure again, LP menu
E1
Steady
Selection error for automatic door operator type (Dip switch 5) or arm type (Dip switch 1 or arm setting on passive brake board)
E2
Steady
Maximum current threshold exceeded error (OVERCURRENT)
E3/E4
Steady
Supervised sensor initialization fail error. Run the LS supervised sensor automatic acquisition procedure again
E6
Steady
No encoder connection error
E8
Steady
no supervised sensor detected.
SO
Steady
supervised sensor detected during opening, on Phot Op input.
S1
Flashing
failed safety test on sensor during opening.
Steady
supervised sensor detected during closing, on Phot Cl input.
S2
Flashing
failed safety test on sensor during closing.
Steady
supervised sensors detected during opening and closing, on Phot Op and Phot Cl inputs.
S3
Flashing
failed safety tests on sensors during opening and closing.
Steady
Stop. The door stopped during opening due to a safety device being triggered
ST
Steady
Temporary Stand by input act
fr
Fig. AD
INSTALLATION MANUAL
jumper
jumper
Descriptions
Right hinge axis
Left hinge axis
VISTA SW SXL - VISTA SW MXL
AD
- 29