Fan Kit Components
The complete #555CFK kit contains
the following:
• Fan & motor unit assembled to
fan mounting bracket c/w wiring
harness, speed control junction
box, thermal sensor switch and 6'
cord set.
• Control box mounting screw and
cable retainer.
• Unit mounting screws
(2).
Preparation
New fireplace installations
If installing the fan kit in a new application, follow
the installation guidelines in the following pages in
conjunction with the installation manual supplied with
the fireplace engine.
Existing fireplace installations
If installing the fan kit in an existing fireplace, start with
the following steps, refering to the installation manual
supplied with the fireplace engine.
1. In a cold fireplace, remove the trims and front
(preceded by the top if 530 free standing stove), the
window, the logs/coals/stones and bricks.
2. Shut-off the gas supply to the fireplace and
disconnect the gas line from the unit's valve.
3. Remove the burner module.
4. If installing in an insert, insure that the metal base
of the fireplace enclosure is supported. If the metal
base can flex up and down, it may be a source of
vibration noise when the fan unit is installed. Now is
the time to correct this.
5. Install the fan according to the guidelines of the next
pages.
2
Fan with motor
4000656
Spade
Terminals
Variable Speed
Control Box
4000522X
Spade
Terminals
Testing the Fan Unit After Installation
Although the fan and controls are factory tested to
ensure proper operation, a check should be performed
after the fan installation, prior to finishing the assembly
of the fireplace.
1. Before energizing the control box, manually bypass
the thermal switch with a jumper either at the
switch or at the spade terminals (be careful not to
short out if using a non-insulated jumper).
2. Plug-in the power cord to energize the control box.
3. Rotate the control knob and check that the fan
operates correctly at all speeds.
Once verified, disconnect the power, remove the
jumper, and reconnect the thermal switch wires to the
control box terminals.
Fan mounting
plate 320B390
Sheet Metal Screws
100A757 (2)
Thread Cutting Screw
4000203 (1)
Clamp self-adhesive
4000536
Thermal Switch
& Lead 4000530
6'-0" Grounded
Plug