Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

CSA approved for use with Valor Models 530I Heaters ONLY
Notes: This kit must be installed or serviced
by a qualified installer, service agency or gas
supplier. These instructions are to be used
in conjunction with the main installation
instructions for the above listed heater
models.
The installation of this kit affects the
framing and method of installing the 530
heater.
Window frame cover
Trim panel—patina, brushed nickel or black
Overview
(530 engine and 570FPB Finishing Plate sold separately)
4002418-03
© Copyright Miles Industries Ltd., 2010.
All manuals and user guides at all-guides.com
P
ortrait
569 Ledge Front
INSTALLATION INSTRUCTIONS
Stud bracket
Cement board
Convection baffle
570FPB Finishing Plate
Trim panel
lead-in
assembly
Installation Sequence
1. Frame the cavity.
2. Install the heater with stud brackets, stand-offs,
insulation, wall switch kit, and cement board.
3. Gas fit and vent heater.
4. Drywall only (no tile, etc.).
5. Assemble and install the mounting frame.
6. Install finishing material (tile, etc.). Finish around or
under 570 Finishing Plate if using it.
7. Assemble and install the trim panel.
Touch control
wall switch
Insulation
Stand-off
Roof
grille
panel
Mounting frame
Stand-off
530 engine
Stud bracket

Publicité

loading

Sommaire des Matières pour Valor Portrait 530I

  • Page 1 All manuals and user guides at all-guides.com ortrait 569 Ledge Front INSTALLATION INSTRUCTIONS CSA approved for use with Valor Models 530I Heaters ONLY Installation Sequence Notes: This kit must be installed or serviced 1. Frame the cavity. by a qualified installer, service agency or gas 2.
  • Page 2 All manuals and user guides at all-guides.com Dimensions & Clearances Cement board 570 Finishing Plate sold separately center of vent Min. 36” (0.9 m) to combustible materials 1/2” (13 mm) min. under bottom of trim for air gap bottom of trim 3-5/16”...
  • Page 3 All manuals and user guides at all-guides.com Framing Wall Finish 30-1/4” (768 mm) to header 3-5/8” (92 mm) cement board supplied 27-3/8” (695 mm) to cement board This is the framing width. Drywall to 23-3/4” (603 mm) wide. Minimum 12-3/4” (324 mm) (Allow extra for rear vent elbow) Wall Finish with 570 finishing plate...
  • Page 4 All manuals and user guides at all-guides.com Installation LOGS & ROCKS VERSIONS ONLY. Grille cannot be used with coal fuelbed version. Install the grille tab at panel inside the appliance: the top a. Insert the grille in the firebox by aligning one of its side edge to the edge of the firebox as indicated.
  • Page 5 All manuals and user guides at all-guides.com c. Pull out the receiver box. Remove the batteries Wall Switch from the receiver box if it contains any. You Harness can remove the ignition wire to improve access Ignition Wire to the receiver. CAUTION DO NOT USE a screwdriver or other metallic object to Antenna...
  • Page 6 All manuals and user guides at all-guides.com 10. Assemble the mounting c. Slide the internal baffle over the screw tips on frame following the the frame’s left piece, under the top piece. Hold steps indicated below. the baffle in place with one hand. Front Fixing points Internal baffle orientation—...
  • Page 7 All manuals and user guides at all-guides.com 12. Apply wall finish on top of drywall. 15. Hook the window trim cover on the top edge of the IMPORTANT: The drywall is assumed to be window frame. 1/2 inch thick. Wall finish material thickness on top of drywall such as tile, brick, and so on: When finishing under optional 570 Plate: 1/2 inch maximum.
  • Page 8 All manuals and user guides at all-guides.com Wiring Diagram Touch Control Wall Switch Connector...
  • Page 9 All manuals and user guides at all-guides.com Repair Parts List Code Description Part Numbers 569LFP Patina 569LFN Nickel 569LFB Black Trim Panel 4002267PA 4002267N 4002267AZ LH Side Lead-in Panel 4002268AZ 4002268AZ 4002268AZ RH Side Lead-in Panel 4002269AZ 4002269AZ 4002269AZ Lower Lead-in Panel 4002270AZ 4002270AZ 4002270AZ...
  • Page 10 All manuals and user guides at all-guides.com ortrait Devanture Ledge 569 DIRECTIVES D’INSTALLATION Homologuée par la CSA pour utilisation avec le foyer Valor 530I SEULEMENT Étapes d’installation Notes : Ce kit doit être installé ou réparé 1. Érigez la charpente d’encastrement du foyer.
  • Page 11 All manuals and user guides at all-guides.com Dimensions et dégagements Panneau de béton Linteau Plaque de nition 570 vendue séparément centre d’évent Min. 36” (0,9 m) des matériaux combustibles Min. 1/2” (13 mm) en bas de la devanture pour circulation d’air bas de la devanture 3-5/16”...
  • Page 12 All manuals and user guides at all-guides.com Encastrement Panneau de gypse 30-1/4” (768 mm) à la base du linteau 3-5/8” (92 mm) panneau de béton (fourni) 27-3/8” (695 mm) à la base du panneau de béton Largeur de l’encastrement. Ouverture du panneau de gypse : 23-3/4”...
  • Page 13 All manuals and user guides at all-guides.com Installation Versions à BÛCHES ET PIERRES SEULEMENT— ne peut être utilisé avec la version charbons. onglet Installez la grille dans la boîte de foyer, couvrant les en haut orifices du haut. a. Insérez la grille dans la boîte de foyer en l’alignant parallèlement au bord de côté...
  • Page 14 All manuals and user guides at all-guides.com c. Tirez le récepteur hors de son support. Enlevez Fil de l’interrupteur les piles du récepteur si elles ont déjà été insérées. Vous pouvez débrancher le fil d’allumage Fil d’allumage afin de faciliter le maniement du récepteur. MISE EN GARDE N’UTILISEZ PAS de tournevis ou autre object Antenne...
  • Page 15 All manuals and user guides at all-guides.com 10. Assemblez c. Glissez le déflecteur interne sur les pointes des l’encadrement selon deux vis du support de montage gauche sous la les étapes indiquées pièce du dessus. Tenez le déflecteur en place ci-dessous.
  • Page 16 All manuals and user guides at all-guides.com 11. Installez l’encadrement sur la caisse du foyer. Le 14. Accrochez la devanture sur l’encadrement en devant de l’encadrement peut être identifié grâce plaçant les trous de serrures de la devanture à 4 vis en saillie qui serviront à fixer la devanture. sur les vis en saillie de l’encadrement.
  • Page 17 All manuals and user guides at all-guides.com Schéma des connexions Bouton manuel Bouton principal de la soupape Interrupteur mural Soupape combinée Connecteur Interrupteur marche-arrêt Bloc interrupteur Terminal rouge Arrêt Marche Câble de 8 fils Câble de l’électrode Antenne Étincelle Étincelle Interrupteur marche-arrêt Thermocourant...
  • Page 18 All manuals and user guides at all-guides.com Liste de pièces Code Description Numéro des pièces 569LFP Patiné 569LFN Nickel 569LFB noir Panneau devanture 4002267PA 4002267N 4002267AZ Panneau intérieur gauche 4002268AZ 4002268AZ 4002268AZ Panneau intérieur droit 4002269AZ 4002269AZ 4002269AZ Panneau intérieur du bas 4002270AZ 4002270AZ 4002270AZ...