Assembly / Changing the shift cable
SHIFTER
SPECTRO GRIP 3 / BANDIX 3
• Slide shifter (1, Fig 4) onto hand-
lebar.
• Add thrust washer (2).
• Mount fixed grip (3) onto end of
handlebar.
• Without applying pressure, slide
shifter against fixed grip.
• Adjust shifter on handlebar and
tighten with bolt (4), allan key 2.5
mm, torque 1.7 Nm (15 in.lbs.).
• Not recommended for use on thin
walled aluminum handlebars such
as Hyperlite
®
type handlebars.
Caution!
• Check that the shifter and
brake lever function properly
and are unobstructed (realign
if necessary).
• Fixed grips (left and right) pro-
vide an axial safety function.
For this reason, they should be
mounted in such a way as to
make sure they do not slip off
handlebar.
4
1
2
4
5
Assembly locating sleeve
• Feed the control cable (5, Fig. 6)
into the locating sleeve, fix at the
appropriate length using the
clampingbolt (1). Allan key
2.5 mm, tightening torque 1,5 Nm
(7 – 8.8 in.lbs).
SPECTRO GRIP 3 / BANDIX 3
3
(Fig. 5)
• Leave the shifter on the handle-
bar.
• No need to move other
components.
• Use only new cable and
compressionless cable housing
• Detach the cable from the
internal hub.
• Remove the cable housing. Cut
the cable off 6" from the shifter
barrel adjuster. Discard the old
cable and cable housing.