16 www.electrolux.com
CAUTION!
Chemical de-scaling agents can
cause damage to the enamel. Fol-
low the instructions of the manu-
facturer.
Cleaning the water drawer and the
steam generator:
1.
Put the water and vinegar mixture
(approximately 250 ml) through the
water drawer into the steam genera-
tor.
Wait for approximately 10 minutes.
2.
Remove the water and vinegar with
the sponge.
11.5 Lamp
WARNING!
Danger of electrocution! Discon-
nect the fuse before you replace
the lamp.
The lamp and the lamp glass cov-
er can be hot.
Before you change the lamp:
• Deactivate the appliance.
• Remove the fuses from the fuse box or
deactivate the circuit breaker.
A
45°
3.
Put clean water (100 - 200 ml) into
the water drawer to flush the steam
generation system.
4.
Remove water from the steam gener-
ator with the sponge and rub dry.
5.
Keep the door open to let the appli-
ance dry fully.
11.4 Removing / inserting the
door
To clean the door remove it.
A
Removing the door
1.
Open the door as far as it goes.
2.
Press down the clamping levers (A)
on the two door hinges.
3.
Close the door until it is at an angle
of approximately 45°.
4.
Hold the door with one hand on each
side and pull it away from the appli-
ance at an upwards angle.
Inserting the door
To insert the door do the above steps in
the opposite sequence.
Replacing the top lamp
1.
Turn the lamp glass cover counter-
clockwise to remove it.
CAUTION!
Be careful when you remove the
door from the appliance. The door
is heavy. There is a risk of injury or
damage to the appliance.
Put the door with the outer side
down on a soft and level surface
to prevent scratches.
CAUTION!
Put a cloth on the bottom of the
interior of the appliance. It pre-
vents damage to the lamp glass
cover and the cavity.