Very important splatters.
No gas at the torch end
Calbration error
Error during download
Save problems
Automatic JOB deletion.
Flow error
Cooling unit disconnected
Water level fault
Push Pull torch detection error
SD card error
File problem
Battery
Fan default.
Flow error
Overvoltage fault
Undervoltage fault
Welding start fault
20
RC-HD1
Arc voltage is too low or too high.
Bad earth connection.
Insufficient gas protection.
Bad gas connection.
An error occured during calibration, it is cancelled
and may be performed again.
The SD card data is wrong or corrupted.
Number of maximum saves exceeded, no saved slots
available.
Some of your JOBs were deleted because they are
incompatible with the new synergies.
Cooling circuit blocked
The cooling unit is not detected while it was present
at the start of the machine.
There is not enough water left in the cooling tank.
-
No JOB detected in the SD card
No memory slot left
The file «...» does not match with the downloaded
synergies
The battery seems drained
The fan is not rotating at the right speed.
-
-
-
-
See welding settings.
Check and put the earth clamp as close as possible to
the welding zone.
Adjust the gas flow.
Check the gas connections
Check that the valve is operating properly
Press next to exit
Check the data.
Delete some of the program to free slots.
The number of slots is limited to a 100.
-
"Check the torch cooling circuit.
It may be necessary to drain the circuit and change
the liquid."
Check the cooling unit connectors.
Add water or check the water level
Check Push Pull torch connectors
-
Free some space on the SD card.
The file was created with synergies which are not
present of the machine.
Change the battery.
Unplug the machine, check it and restart it.
Cooling circuit to be checked
Check your mains power supply.
Check your mains power supply and three phase
connections.
Check that the wire feeding flow is correct and the
power supply installation (voltage, 3 phases).
EN