Door reset
Reversal of opening/closing side
of the door
See p.
12
The door does not close completely
The door closes slowly
The door does not move
The door get jammed when opening
The door get jammed when closing
Horizontal security failure
The closing speed setting (C7) is inactive
The door opens 50 cm and stops ; «door
closed» is displayed on the control
keyboard
- The control keyboard does
not switch on
- The green light on the
alimentation card is off
1 1
1 1
7 8 9 10 11 12 13 14 15 16 17
4 5 2
2
6
3 3
A
• Set the parameter C8 to 0
• Close manually the door
• Hold on the 4 buttons of the control keyboard during 3 seconds then release (initia-
lization display appears)
• Do opening command (push-button, badge, etc...)
• The door does its setting once more and stops in closed position. (When setting is
finished, «OK» appears on display)
- The belt guide is absent or broken
- There's an obstacle on the path of the door : remove the obstacle then do
an initialization process
- Vertical security out of order or excessive friction
- Normal operation: the door closing speed is lower than the opening speed
- Check that the motor cable and the encoder cable are plugged into the
command box (see p.4)
- Check the power supply
- Check the position of the stop buttons
- When door stops, activate an opening command to open it.
- After 5 failures, when activating an opening command, the door starts an
initialization cycle to reset. Remove any obstacles.
- After 5 attempts to automatically close, the door stops.
- Remove any obstacles then activate an opening command: the door starts
an initialization cycle to reset.
- When the cell(s) fails for more than 30 secondes, it's possible to close the door
by pressing and holding the opening command.
Only «press and hold» commands (see p. 6) allow this function.
- This setting can be adjusted only if a vertical security (option) is connected
- With a vertival buffer (or positive vertical security out of order), the parameter C7
can't be adjusted ; the closing speed is set to minimum
Encoder failure. Check :
- If the cover of the encoder is in place on the motoreducer
- If the cover of the encoder is not damaged
- If the connector of the encoder is well connected under the command box
- If the cable of the encoder is not pinched or damaging
- Check the power supply
- Check the position of the circuit breaker inside the command box
- If a device is plugged into the terminal block (power 24Vcc connecting terminals):
check that there is no short circuit or if the power consumption doesn't exceed 500 mA.
2 2 2 2 2
2 18
19
B C D E
Position des shunts en configuration usine
Location of the links/Factory settings
Position des Kabels/Set-up Fabrik
Cellule de sécurité horizontale
A
Cell for horizontal safety device
Zelle/Horizontale sicherheitsvorrichtung
B
Détection incendie / Fire detection / Branderkennung
C
Commande d'arrêt 1/2 / Stop command 1/2
Stopp-Steuerbefehle 1/2
D
E
Verrou ou serrure / Lock / Verriegelung oder Schloss
24
Kit5010Exp_Elec-D