Commissioning
7.3.5
connect the device to the
transmitter
4
1
2
3
Fig. 9:
Pin assignment of the fixed connector
Terminal block
of the connector
1
2508
3
2
FE = functional earth
terminal
Fig. 10: Connection example of the 8220 to the transmitter 8619
Type 8220
1: Positive conductivity electrode
2: Pt1000
3: Negative conductivity electrode
4: Pt1000
1 2 3 4 5 6 7 8 9
Conductivity module of the
transmitter 8619
8
commissioning
Warning
risk of injury due to non-conforming commissioning.
Non-conforming commissioning could lead to injuries and damage
the device and its surroundings.
▶ The staff in charge of commissioning must have read and under-
stood the contents of the Operating Instructions.
▶ In particular, observe the safety recommendations and intended
use.
▶ The device / the installation must only be commissioned by
suitably trained staff.
→
Before commissioning, set the cell constant in the appropriate
parameter menu of the remote transmitter. Refer to the Operating
Instructions of the transmitter used.
English
17