Télécharger Imprimer la page

Tristar AC-5564CH Mode D'emploi page 8

Publicité

Les langues disponibles

Les langues disponibles

Instruction manual
Exhaust hose installation
The exhaust hose can be removed from the machine by rotating it in
the arrow direction as illustrated by (1) diagram.
The exhaust hose can be installed at the machine by rotating it in the
arrow direction as illustrated by (2) diagram.
Window kit installation
Install the Exhaust Hose and the Adjustable Window Slider Kit as shown in
figure 1 or figure 1a.
8
USE
Power button: Press to turn unit "ON" or "OFF".
Temp- (down):During cooling function this key lowers the preset
temperature by 1
o
C each time it is pressed and the minimum limit is
17
o
C. During heating function this key lowers the preset temperature
by 1
C each time and the minimum limit is 15
o
Speed: Press to select either low, medium, or high fan speed. Note: In
dehumidifying function, this key is invalid because the unit is defined
to be low speed in dehumidifying mode.
Temp+ (up): During cooling function this key raises the preset
temperature by 1
C each time it is pressed and the maximum limit is
o
30
C. During heating function this key raises the preset temperature by
o
1
C each time it is pressed and the maximum limit is 25
o
Programmable timer: The timer-on is used to turn on the unit
automatically after the set time is over. Press the "timer" button at stand-
by status , then set the time you desired by pressing "temp+" or "temp-"
button. Once the set hour has come to an end, the unit will turn on
automatically. Press the "power" button before time out, the setting time
will be canceled and the unit will turn on. You can set the function and
fan speed while setting the timer. The timer-off is used to turn off the
unit automatically after the setting time is over. Press the "timer" button
at operating status ,then set the time you desired by pressing "temp+"
or "temp-" button. Once the set hour has come to an end, the unit will
turn off automatically. Press the "power" button before the time out, the
setting time will be canceled and the unit will turn off.
Mode: Press this key to select cooling, fan, dehumidifying or heating.
Alarm
When the water tank is full, " E2" will be displayed on the display panel. To
resume operation, please remove the rubber cap of the drain, hose to
drain out the water firstly. The E2 warning will disappear after draining,
and then you can restart the unit by pressing the power button.
LED display
The display indicates the current setting temperature or the timer
setting. When the set temperature or the timer is adjusted, the new
setting is shown then the display returns the current set temperature.
The display is also used to show error codes should a fault occur.
Air filter function
If there is a large amount of dust on the net, the air volume will be
reduced.
C.
o
C.
o

Publicité

loading