minutes before restarting. This to prevent the
compressor from being damaged.
• This unit needs at least 7 Amps of electricity to have
its compressor operational.
• To avoid the household electricity block out, please
do not use any extension cord for this unit.
• This unit is for indoor cooling, heating and
dehumidifying.
• In order to dispose the appliance safely, please
remove the batteries from the unit before
scrapping it.
WARNING
Specific information regarding appliances with R 290
refrigerant gas.
• Thoroughly read all of the warnings.
• When defrosting and cleaning the appliance , do
not use any tools other than those recommended
by the manufacturing company.
• The appliance must be placed in an area without
any continuously sources of ignition (for example:
open flames , gas or electrical appliances in
operation).
• Do not puncture and do not burn.
• Appliance shall be installed, operated and stored
in a room with a floor area larger than X m2. (X=12
for 9000Btu/h,10500Btu/h; X=15 for 12000Btu/
h,140000Btu/h)
• This appliance contains Y g (see rating label back of
unit ) of R290 refrigerant gas.
• R290 is a refrigerant gas that complies with the
European directives on the environment. Do not
puncture any part of the refrigerant circuit.
• If the appliance is installed, operated or stored in
a non ventilated area, the room must be designed
to prevent to the accumulation of refrigerant leaks
resulting in a risk of fire or explosion due to ignition
of the refrigerant caused by electric heaters, stoves,
or other sources of ignition.
• The appliance must be stored in such a way as to
prevent mechanical failure.
• Individuals who operate or work on the refrigerant
circuit must have the appropriate certification issued by
an accredited organization that ensures competence in
handling refrigerants according to a specific evaluation
recognized by associations in the industry.
• Repairs must be performed based on the
recommendation from the manufacturing
company. Maintenance and repairs that require
the assistance of other qualified personnel must be
performed under the supervision of an individual
specified in the use of flammable refrigerants.
REFRIGERANT
(CE) N 842/2006: This air conditioner contains the refrigerant R290. The
amount of refrigerant is less than 1kg, and is in a closed cooling circuit.
The coolant does have zero ozone depletion potential, but is a so-called
greenhouse gases under the Kyoto Protocol and may thus contribute to
global warming, if it is released to the atmosphere. Therefore only trained
technicians with refrigerant certificate make a filling or emptying. Your air
conditioner does not have be refilled with refrigerant if used properly and
has an undamaged coolant circuit. GWP: R290: 3
Air conditioner
EN
5