General Instructions; Preparation; The Chimney Flue - WANDERS Elm Mode D'emploi Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
The Elm side panels and the base can be made from various materials and undergo several diff erent kinds of
processing and colouring. WANDERS cannot guarantee complete uniformity of colour between the various parts.
Any complaints will be dealt with after the sales fi rm, the installer has fi led a complaint and sent a copy of the
purchase receipt with purchase date. Any repairs do not entitle you to extend the guarantee term. All consequential
damages or loss are excluded.

General instructions

The Elm is tested in accordance with the international EN 13240 standardization, and has an extra additional
standardization for optimally environment-friendly heating devices related to fl ue gases. The stove can be
connected to a fl ue tube to which several stoves are connected. The fl ue tube has a diameter of 150 millimetres.
The heating device must be placed by an acknowledged installer and according to the installation instructions
given below. The national and local rules and regulations for placing and using wood-burning stoves are equally
applicable. WANDERS does not give any guarantee if the Elm is connected or installed incompletely or incorrectly.
It is not allowed to place the stove in:
Arcades and corridors accessible to the public.
Stairwells, except in buildings with no more than 2 dwellings.
Spaces where highly fl ammable or explosive materials are used.
Spaces where an exhaust system is used or where a mechanical exhaust system is placed, except when the air
supply is taken directly from outside to assure a hazardless combustion.

Preparation

The chimney fl ue
Before placing the stove you must observe the following points:
If the stove is connected to an existing chimney, you must fi rst have the chimney professionally cleaned and
checked by a qualifi ed chimney sweep company. Any cut-off valves or stop valves must be removed.
The fl ue tube of the stove must be connected with the chimney without diversions.
The underpressure in the chimney must be at least 12 Pa or 0.12 mbar.
The chimney fl ue must always end up in outlet area 1 (see drawing below)
At the time of placing the stove, the chimney
fl ue must be clean, leak-proof and without
obstructions, and must have a diameter of
150 mm.
Any bends in the fl ue tube must not exceed
45 degrees.
Ensure that the chimney tube can discharge
the fl ue gases adequately, properly and
safely.
The values for calculating the chimney
tube is given in the section on Technical
Information, page 26.
22
1
3
3
A X
X > 23˚
1
X
500 mm
X < 23˚
3

Publicité

Table des Matières
loading

Table des Matières