Selecting And Changing The Nosepiece; To Set A Blind Rivet; Sucking In And Holding A Blind Rivet; Emptying The Spent Mandrels From The Container - Gesipa PH 2000 Mode D'emploi Avec Pièces De Rechange

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
7.1

Selecting and changing the nosepiece

Caution:
Always fit the nosepiece corresponding to the size of the blind rivet (refer to table in
Section 6).
To change the nosepiece:
Disconnect the tool from the compressed air supply.
Unscrew nosepiece from steel head sleeve.
Screw in corresponding nosepiece and tighten.
7.2

To set a blind rivet

Connect the riveting tool to the compressed air supply.
Insert the blind rivet in the nosepiece and fit as far as it will go in the hole in the material
to be joined.
Press trigger until the mandrel breaks off.
Release trigger.
The spent mandrel is automatically conveyed into the spent mandrel container.
8.

Sucking in and holding a blind rivet

Special function VAS
The setting screw marked with "VAS" is reached with the supplied ball end screwdriver.
Turning the screw 1 to max. 1.5 turns clockwise creates the suction air that holds the
blind rivet in the nosepiece.
Only turn the setting screw so that the suction air holds the vertical blind rivet against the
nosepiece.
Turning the screw anticlockwise shuts off the suction air.
9.

Emptying the spent mandrels from the container

Caution:
The spent mandrel container must be emptied regularly; overfilling will cause the
riveting tool to malfunction.
Disconnect the tool from the compressed air supply.
Open the spent mandrel container by turning the outer casing, empty spent mandrels into
suitable container and dispose of in corresponding recycling system.