INSTALLATION INSTRUCTIONS CONTROL PANEL 3010 613
Control panel 3010 613 is intended for the Alde Compact 3010 boiler.
7KH FRQWURO SDQHO VKRXOG EH ORFDWHG DW OHDVW PHWUH DERYH WKH ÀRRU EXW QRW WRR FORVH WR WKH FHLOLQJ 1RU VKRXOG LW EH
located on an outer wall or close to objects which radiate heat, for example, CD players, refrigerator and lamps, as this
can give incorrect temperature. The area behind the panel should be well ventilated. If the room temperature on the
panel is affected nevertheless, an external sensor should be connected to the panel.
0DNH D KROH IRU WKH SDQHO DV VKRZQ LQ ¿JXUH & 6FUHZ GRZQ WKH SDQHO DQG SXVK WKH IURQW SDUW RQ &OLS RQ WKH FDEOHV WR
avoid wear on the terminal strip of the panel.
A.
86 mm
CABLE CONNECTION BETWEEN BOILER COMPACT 3010 AND CONTROL
PANEL 3010 613
Connect accessories to the control panel as shown in the diagram below. N.B. Do not cramp 12 V cables or sensor
cables together with 230 V cables. It is preferable not to place the cables close to each other. If the cables are bund-
led, the risk of shutdown increases.
%DFN RI FRQWURO SDQHO
External sensor, blue (F)
Load monitor, green (E)
External start of boiler, yellow (D)
Change LPG cylinder (C)
18
B.
9 mm
Remote sensor, white (G)
Pump signal (B)
1
6
2
7
EXT
8
3
4
9
10
5
38,5 mm
+
red
B
C D E F (G) (H) I
J
BZI
R30
+
C8
JP1
JP6
C.
76 mm
73 mm
R3(4x)
Battery Back-up (3V DC) (H)
Window breaker (I)
Heating of reduction valve
(Eis Ex) (J)
C23
JP4