10. Service and Resetting the system
Service
Reset
10:1 Service menus
Activated
Functions
11. Fault messages
+22°C
Gas failure
16
1. Service
With this function, you can see
1
certain values of the boiler on
2
the screen. The values are
updated once a second
3
OK
2. Resetting the system
Using this function, the boiler
can be reset to the factory set-
ting. After resetting, the panel
is set as follows: the boiler in
Heater temp:
Sanitary temp:
If an error occurs in the system, the display will show the reason.
This is only displayed when the panel is on standby.
Battery too low: If the vehicle, boat or building has a battery voltage of
less than 10.5V, the boiler stops. It is automatically reset when the voltage
reaches 11V.
)DQ IDLOXUH Faulty fan speed. In order to reset, disconnect 12V from the
boiler and reconnect (automatic reset after 5 minutes).
*DV IDLOXUH *DV ¿QLVKHG 5HVHW E\ VZLWFKLQJ RII DQG UHVWDUWLQJ WKH ERLOHU
in accordance with item 1.
2YHUKHDW UHG IDLO Overheating protection (red cable) triggered. To reset,
disconnect 12V from the boiler and reconnect.
2YHUKHDW EOXH IDLO Overheating protection (blue cable) triggered. To
reset, disconnect 12V from the boiler and reconnect.
Window open: Window open, the boiler stops for gas. Gas operation in
the boiler starts again when the window is closed. The electrical opera-
tion remains in function. Check the vehicle, boat or building manual to see
whether this function is installed.
&RQQHFWLRQ IDLOXUH There is a connection fault between boiler and panel.
To reset, disconnect 12V from the boiler and reconnect.
3DQHO IDLOXUH Panel fault.
3DQHO IDLOXUH Panel fault.
Off mode, electrical operation
1kw, LPG heating in On mode
and indoor temperature 22°C.
Other functions are discon-
nected.
3. OK
To leave the tool menu, press
OK.
Fan rotation:
RPM
Current:
A
Current:
Overheat:
deact/act
Window switch:
deact/act
Extern start:
deact/act
Soft Rev.
Heater:
Panel:
Cl Version: