9. Automatic temperature increase
(legionella)
At 02.00 at night (if the clock is set) the
boiler starts and works according to "Warm
Water" (see section 5). This is in order to
reduce the risk of legionella. The function
is disconnected in the factory setting.
10. 2IIVHW WHPSHUDWXUH DGMXVWPHQW
Using this function, you can calibrate the
temperature on the panel if you notice that
the temperature (the stabilised room tem-
perature) is not the same as the tempera-
ture shown on the panel. This also applies
to outdoor temperature.
11. Button sound
With this function, you can connect or dis-
connect the button sound.
The button sound is connected in the fac-
tory setting.
12. Luminance
The luminance can be adjusted between
1-10. The factory setting is 2.
13. Language
Lan
This function is used to reset the screen
between different languages. Available
languages are: English, French and Ger-
man. On the other hand, the service menu
is only in English (see section 10.1).
14. 7RROV  .H\
Under Tools / Key you can lock or unlock
access to the tool menu.
15. *External start
Ext
This function is used when starting the
boiler from the outside, for example, with
GSM. When external start has been acti-
vated, the control panel's On/Off button
must be switched off (see the assembly
setting manual for external start). NOTE!
7R XVH WKLV IXQFWLRQ DQ H[WHUQDO VWDUW
installation is required (see the manual
IRU WKH YHKLFOH ERDW RU EXLOGLQJ 
*230 V
This function is used in connection with
starting the boiler when connection of
230 V to vehicle takes place from outside.
When the 230 V function has been activa-
ted the control panel's on/off button must
be turned off, but 12 V must be connected
(main switch on). Before turning off the
control panel with the on-/off button set the
parameters/functions that you want the
boiler to have when it starts (230 V is con-
nected).
16. *Load monitor
Amp
This function is used to prevent the 230V
fuses being overloaded. If the total power
consumption of the vehicle, boat or build-
ing exceeds the set value, the boiler's
power will be automatically reduced. On
account of voltage variations and toler-
ances, different setting levels can be
selected (for example, for 6A fuse, one
can choose 6 or 7 Amp setting). If the fuse
does not hold, choose a lower set value.
The function is disconnected in the factory
setting. NOTE! The load monitor has to
EH LQVWDOOHG IRU WKH IXQFWLRQ WR EH XVHG
VHH WKH PDQXDO IRU WKH YHKLFOH ERDW RU
building).