Télécharger Imprimer la page

Elvox Vimar SL24.W Guide Rapide Installateur page 26

Carte de commande avec écran et récepteur radio 433 mhz intégré

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
SL24.W
List of signalling on the display
Signal
Description
C1
Contact closed on command C1 input
C2
Contact closed on command C2 input
C3
Contact closed on command C3 input
C4
Contact closed on command C4 input
S1
Contact open on safety device S1 input
S2
Contact open on safety device S2 input
S3
Contact open on safety device S3 input
S4
Contact open on safety device S4 input
FO1
Opening limit switch position reached
FC1
Closing limit switch position reached
OBO
Obstacle detected on opening
OBC
Obstacle detected on closing
Motor in stop approach force reduction
AF1
interval
MSO1
Mechanical stop reached in opening
MSC1
Mechanical stop reached in closing
Operation with battery
When this message is displayed it is fol-
BATT
lowed by an indication of the battery oper-
ating voltage, e.g. 24.5V
Battery almost flat (indication shown only
BT-
when the gate is stopped)
Battery totally flat (indication shown only
BT--
when the gate is stopped)
Radio command received from saved re-
RX
mote control
Radio command received from unsaved
NX
remote control button
RD
Rolling/fixed code decoding off
OAB
Gate left open
AT
Gate in self-calibration
List of alarms
Alarm
Description
XXXX
Reset card
Manoeuvre interval since last maintenance
MNP
reached alarm
F0
Error motor not selected
F1
Motor cables inverted error
F3
Reversed limit switch error
F4
Both open limit switch alarm
F5
Opening limit switch malfunction error
F6
Closing limit switch malfunction error
F9
Communication error with expansion card
F10
Error alarm motor not connected
F12
Encoder error alarm
Microswitch undervoltage (check power sup-
F14
ply and outputs)
F15
Safety test 1 failed
F16
Safety test 2 failed
24
F17
Safety test 3 failed
F18
Safety test 4 failed
F19
Manoeuvre length/timeout alarm
F21
Mosfet short alarm
F23
Blocked rotor alarm
F26
5th obstacle in closing alarm
F27
Overcurrent alarm
F29
Radio memory full alarm
F30
Faulty radio memory alarm
F31
Short flashing alarm
F32
Gate open light short alarm
F33
No memory card alarm
F34
FW checksum alarm
F36
Board temperature alarm
Updating Firmware:
The control panel is equipped with a USB port that is used
to update the control panel Firmware or the Wi-Fi EMC.W
communication module Firmware
Caution:
If the firmware updating procedure is not carried out prop-
erly it may damage the control panel or the Wi-Fi com-
munication module, make sure not to interrupt the mains
power supply during the update.
To perform the Firmware Update, consult the instructions
provided with the Firmware
EN

Publicité

loading