SL24.W
Connection module
Sub
Description
menu
Connection module on CNX1
connector
CNX1
No module connected
Wi-Fi module EMC.W connected
Connection module on CNX2
connector
No module connected
Opposing leaf module EMX.W
CNX2
connected. Control panel function-
ing as MASTER
Opposing leaf module EMX.W
connected. Control panel function-
ing as SLAVE
Restore default values and loading from memory
card
Sub
Description
menu
Loading the default values
Waiting press OK for 5 s to load
the default values.
Note:
DEF
Loading the default values then requires the
travel to be calibrated again, LRNT flashes
on the display until (rapid or advanced)
calibration is done.
Loading the programming from
memory card
Waiting press OK for 5 s to load
the values from memory card.
MEM
Loading from memory card com-
pleted OK.
Loading from memory card error
(e.g. no card).
Control panel protection level settings
(default = OFF)
OFF No protection
Protection of menus MOT, LRNT, TRV, OUT,
1
IN, LGC, STAT, EXP, LOAD
2
Protection of menu RAD
Protection from IP connection (it is not pos-
3
sible to connect to the control panel from a
smartphone)
Protection of menus MOT, LRNT, TRV,
4
OUT, IN, LGC, STAT, EXP, LOAD and IP
connection
5
Protection of menu RAD and IP connection
6
Complete control panel protection
Protection of all board menus, IP connection
7
available
Values
(default)
(1)
OFF
1
(OFF)
OFF
1
2
Msg
display
oooo
oooo
DONE
EMEM
EN
23