SL24.W
Deletion of single remote control
from its position in the memory
Use buttons ▲▼ to select the
ERS1
number of the remote control to
delete
Press OK to confirm
Deletion of single remote control
from the remote control code
ERSR
Waiting for code
Deleting remote control
Diagnostics and reporting
Sub
Description
menu
Alarm log reading
Most recent alarm
ALM
Oldest alarm
Error signalling (default = 1)
Only on display
ALMA
On display and maintenance
output
Reading of number of manoeu-
vres since last maintenance
First 3 digits of the number of ma-
noeuvres since last maintenance
MNPC
Last 3 digits of the number of ma-
noeuvres since last maintenance
In the case described above, the gate has
carried out 23,256 manoeuvres since the last
maintenance
Number of manoeuvres since
last maintenance
Number of manoeuvres generat-
ing a maintenance signal (in thou-
sands of manoeuvres) (default
= OFF)
MNPS
Maintenance signalling off
1,000 manoeuvres (minimum
interval)
300,000 manoeuvres (maximum
interval)
Maintenance signalling
(default = 1)
Signalling only on display
Signalling on display and mainte-
nance output (MAN)
Signalling on display and flashing
MNPA
light (rapid flashing at end of
manoeuvre)
Signalling on display, flashing
light (rapid flashing at end of
manoeuvre) and maintenance
output (MAN)
Reset manoeuvres since last
maintenance counter
MNPE
Waiting press OK for 5 s to reset
the counter to 0
22
Total manoeuvres counter
First 4 digits of the number of ma-
noeuvres since last maintenance
Last 4 digits of the number of ma-
MNTC
X
noeuvres since last maintenance
In the case described above, the gate has
carried out 125,874 manoeuvres in total
Life counter (days of activity of
the control panel)
oooo
Reading of the number of days of
LIFE
activity of the control panel
In the case described above, the control
Msg
panel was active for 584 days
display
Number of control panel power-
ups counter
0
Reading of the number of control
10
panel power-ups
PONC
In the example shown above, the control
1
panel was powered up 2547 times (it could
2
indicate a poor quality mains electricity, with
frequent power cuts)
Reset number of control panel
power-ups counter
PONE
23
Waiting press OK for 5 s to reset
the counter to 0
256
Number of self-reset counter
Reading of the number of control
panel self-resets
A self-reset is a reset of the microswitch
by the control panel for safety reasons.
Typically the control panel goes to self-reset
RSTC
when the minimum microswitch voltage
threshold has been reached. An excessive
number of self-resets could indicate a poor
quality power supply, subject to strong volt-
age fluctuation.
OFF
Reset number of self-reset
1
counter
RSTE
Waiting press OK for 5 s to reset
the counter to 0
300
Installer telephone settings and
display
Press OK briefly to view the
1
saved number (use buttons ▲▼
to scroll)
2
First 4 digits of the installer number
Next 4 digits of the installer
TL
3
number
Last 2 digits of the installer number
In the example shown above the installer
telephone number is: 333 4254832
4
Press OK for 5 s to enter the number edit
mode. Use buttons ▲▼ to change the
value, use OK to confirm the digit
Control panel info display
INF
Control panel name
oooo
Control panel firmware version
EN
12
5874
584
2547
oooo
1123
oooo
3334
2548
32
SL24.W
1.13