INSTALLER FINAL CHECKLIST

18
US
CA
GENERAL
Placement of unit.
Specified clearance maintained to cabinet surfaces.
Unit Level - front to back, side to side.
All packaging material and tie straps removed.
Backguard attached if there is less than 12" clearance from the back edge of the cooktop to combustibles behind
unit.
Radiant tray placed in grill unit (if equipped). Grill rack in place.
ELECTRICAL
Receptacle with 15 ampere over-current protection is provided for service cord connection.
Adequate ground connection.
GAS SUPPLY
Connection: 1/2 NPT with a minimum 5/8" diameter flex line. Site gas supply is compatible with cooktop model,
and sufficient pressure is available (see section 'Gas Hook-up').
The pressure regulator which is connected to the manifold is set for 5.0" W.C. for natural gas or 10.0" W.C. for LP.
Manual gas shut-off valve installed in an accessible location.
Unit tested and free of gas leaks.
OPERATION
All internal packing materials removed.
If used on LP gas, verify that pressure regulator, orifice hoods, air shutters, and valve jets have been set for use
with LP gas.
Grill compartment seated and does not rock (if equipped).
Bezels centered on burner knobs and knobs turn freely.
Each burner lights satisfactorily, both individually and with other burners operating at the same time.
Griddle is level and does not rock (if equipped).
Burner grates correctly positioned, level, and do not rock.
Griddle flame (see section 'Test and adjustments').
Grill flame (see section 'Test and adjustments').
Cooktop burner flame (see section 'Test and adjustments').