INSTALLER FINAL CHECKLIST
14
US
CA
GENERAL
❏
Placement of Unit.
❏
Specified clearance maintained to cabinet surfaces.
❏
Unit Level- front to back, side to side.
❏
All packaging material and tie straps removed.
ELECTRICAL:
❏
Receptacle with 15 ampere circuit protection is provided for service cord connection.
❏
Adequate ground connection.
GAS SUPPLY:
❏
Connection: 1/2" NPT flex line with a minimum 5/8" diameter.
❏
The pressure regulator which is connected to the manifold is set for 4.0" W.C. for Natural Gas or 10" W.C.
for LP.
❏
Manual gas shut-off valve installed in an accessible location.
❏
Unit tested and free of gas leaks.
OPERATION:
❏
All internal packing materials are removed, i.e. below grates, around knobs, etc.
❏
Bezels centered on burner knobs and knobs turn freely.
❏
Each burner lights satisfactorily, both individually and with other burners operating.
❏
Low flame operation verified.
❏
All burner caps, burner rings and burner bases correctly seated in position, level, and do not rock or slide.
❏
Burner grates correctly positioned, level, and do not rock.