Key
Display
Description
INFO
Access to information menu, various system statuses, temperatures and operating information can be called up here.
IN
INFORMATION INPUTS
FLAME
Display of current flame temperature.
319
ROOM
Display of current room temperature.
Menü
22
R-MAX
Display menu maximum duration without connection to wireless room sensor
Menü
EXT
Display of status of external release. (ON or OFF)
Menü
ON
DOOR
Display of the status of door contact. (ON or OFF)
Menü
ON
STB
Display of the status of safety temperature limiter. (ON or OFF)
Menü
ON
CSENS
Display of the current C-sensor value
Menü
IN
INFORMATION INPUTS
Menü
OUT
INFORMATION OUTPUTS
Menü
AUGER
Display of operating status of screw motor. (ON or OFF)
OFF
AUGER
Display of actual push-in rate.
Menü
00
FAN
Display of operating status of flue gas blower. (ON or OFF)
Menü
ON
FAN
Display of speed of flue gas blower.
Menü
00
C-FAN
Display of the operating status of the cross-flow fan. (ON or OFF)
Menü
ON
C-FAN
Display of the speed of the cross-flow fan.
Menü
00
IGNIT
Display of operating status of ignition element. (ON or OFF)
Menü
OFF
OUT
INFORMATION OUTPUTS
Menü
PAR
INFORMATION PARAMETER
Menü
RUN – T
Display of previous total operating hours.
63
RUNKG
Display of total pellet amount supplied up to present.
Menü
245
Display of conveyed pellet amount since the last cleaning and maintenance.
SERKG
The value is reset to 00 after confirming the service notification.
Menü
245
(see chapter 12. CLEANING AND MAINTENANCE)
MEMO
Display of current software version loaded on control board. (ticker)
Menü
130
PMSM
Display current software version on additional circuit board
Menü
003
U-VER
Display of current software version loaded on control unit.
Menü
13
PAR
Repeated pressing of
Menü
English
returns you to the main menu level.
Menü
43