Transmission
If [TABLE] is selected, operating a parameter specified in the [Control assign ta-
ble] will cause these messages to be transmitted if [Control Change Tx] is ON.
The parameters that can be specified are defined in the Control Change Assign
Parameter List.
If [NRPN] is selected, operating a specified parameter will cause data to be
transmitted on the [Tx CH] if [Control Change Tx] is ON, using the four mes-
sages NRPN control number (62h, 63h) and Data Entry control number (06h,
26h). Parameter settings are defined in the Control Change Assign Parameter
List.
This data cannot be transmitted via control change to Studio Manager since
there is no guarantee that the contents of the tables will match. (Parameter
Change messages will always be used.)
If [TABLE] is selected
Control change
STATUS
1011nnnn Bn
Control number (0-95, 102-119)
DATA
0nnnnnnn nn
Control Value (0-127)
0vvvvvvv vv
If [NRPN] is selected
Control change
STATUS
1011nnnn Bn
NRPN LSB
DATA
01100010 62
LSB of parameter number
0vvvvvvv vv
Control change *1
STATUS
1011nnnn Bn
NRPN MSB
DATA
01100011 63
MSB of parameter number
0vvvvvvv vv
Control change *1
STATUS
1011nnnn Bn
MSB of data entry
DATA
00000110 06
MSB of parameter data
0vvvvvvv vv
Control change *1
STATUS
1011nnnn Bn
LSB of data entry
DATA
00100110 26
LSB of parameter data
0vvvvvvv vv
*1) The second and subsequent STATUS need not be added during
transmission. Reception must be implemented so that reception oc-
curs whether or not STATUS is present.
2.4 PROGRAM CHANGE
Reception
If [Program Change ECHO] is ON, these messages are echoed from MIDI
OUT.
If [Program Change RX] is ON and the [Rx CH] matches, these messages will
be received. However if [OMNI] is ON, they will be received regardless of the
channel. When a message is received, a Scene Memory will be recalled according
to the settings of the [Program Change Table].
Transmission
If [Program Change TX] is ON, this message is transmitted according to the set-
tings of the [Program Change Table] on the [Tx CH] channel when a scene
memory is recalled.
If the recalled scene has been assigned to more than one program number, the
lowest-numbered program number will be transmitted. Transmission to Studio
Manager using Program Change messages will not be performed since there is
no guarantee that the contents of the tables will match. (Parameter Changes will
always be used.)
Program change
STATUS
1100nnnn Cn
Program number (0-127)
DATA
0nnnnnnn nn
2.5 SONG POSITION POINTER
Reception
If this is received when the automix TIME REFERENCE setting is MIDI
CLOCK, the automix will move to the song position that was received.
Song position pointer
STATUS
11110010 F2
Song position LSB
DATA
0vvvvvvv vv
Song position MSB
0vvvvvvv vv
2.6 TIMING CLOCK
Reception
If the automix TIME REFERENCE setting is MIDI CLOCK, this message is used
to synchronize automix. It is also used to control effects. This message is trans-
mitted 24 times per quarter note.
Timing clock
STATUS
11111000 F8
2.7 START
Reception
This message is received if the automix TIME REFERENCE setting is MIDI
CLOCK, and will start the automix. In actuality, automix will start when the
next TIMING CLOCK is received after receiving the START message.
STATUS
11111010 FA
2.8 CONTINUE
Reception
This message is received if the automix TIME REFERENCE setting is MIDI
CLOCK, and will cause automix to start from the current song position. In ac-
tuality, automix will start when the next TIMING CLOCK is received after re-
ceiving the CONTINUE message.
STATUS
11111011 FB
2.9 STOP
Reception
This message is received if the automix TIME REFERENCE setting is MIDI
CLOCK, and will cause automix to stop.
STATUS
11111100 FC
2.10 ACTIVE SENSING
Reception
Once this message has been received, the failure to receive any message for an
interval of 400 ms or longer will cause MIDI transmission to be initialized, such
as by clearing the Running Status.
STATUS
11111110 FE
2.11 SYSTEM RESET
Reception
When this message is received, MIDI communications will be cleared, e.g., by
clearing the Running Status.
(Cn)
STATUS
11111111 FF
2.12 SYSTEM EXCLUSIVE MESSAGE
2.12.1 MIDI MACHINE CONTROL
These messages are transmitted when the Machine Control section of the
DM1000 is operated.
2.12.2 BULK DUMP
This message sends or receives the contents of various memories stored within
the DM1000.
The basic format is as follows.
For DUMP DATA
F0 43 0n 7E cc cc <Model ID> tt mm mm [Data ...] cs F7
For DUMP REQUEST
F0 43 2n 7E <Model ID> tt mm mm F7
n
cc cc
4C 4D 20 20 38 43 39 31
(F2)
tt
mm mm
cs
A unique header (Model ID) is used to determine whether the device is a
DM1000.
CHECK SUM is obtained by adding the bytes that follow BYTE COUNT
(LOW) and end before CHECK SUM, taking the binary compliment of this
sum, and then setting bit 7 to 0.
(F8)
CHECK SUM = (-sum)&0x7F
Reception
This message is received if [Bulk RX] is ON and the [Rx CH] matches the device
number included in the SUB STATUS.
When a bulk dump is received, it is immediately written into the specified
memory.
When a bulk dump request is received, a bulk dump is immediately transmit-
ted.
Format des données MIDI
Start
Continue
Stop
Active sensing
System reset
(MMC)
Device Number
DATA COUNT (the number of bytes that
follow this, ending before the checksum)
Model ID
DATA TYPE
DATA NUMBER
CHECK SUM
DM1000 Version 2—Mode d'emploi
367
(FA)
(FB)
(FC)
(FE)
(FF)
(F0)