-Brazier not fed with
pellets.
NO PELLETS
-Occurs in case of cutting
AL 7
in of auger duct
THERMAL
temperature safety
thermostat.
SAF
-The system is stopped.
-In the work stage the
AL 8
stove detects a pressure
NO NEG
below the vacuum switch
setting threshold.
PRESS
-The system is stopped.
AL 9
-Appears when the
INSUFF
combustion air flow is
below a certain threshold.
DRAUGHT
-Occurs when the
AL b
gearmotor works
AUG TRIAC
continuously and for more
than 60 sec.
ERROR
-The system is stopped.
-Occurs on relighting the
WAITING
stove immediately after
COOL
having shut it down.
AIR FLOW
-Occurs when the air flow
METER
meter is disconnected.
FAILURE
- Occurs when the stove
has exceeded 1800 hours
SERVICE
of operation or 2000 Kg
DUE
pellet, since the previous
servicing.
The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice.
The drawings, measurements, diagrams and any other configurations are given only by way of example.
-The pellet hopper is empty.
-The pellet feed gearmotor has
to adjust.
-The gearmotor does not
feed pellets.
-The safety thermostat has
detected a temperature
above the setting threshold
due to overheating of the
bottom part of the hopper,
blocking gearmotor
operation.
-The combustion chamber is
dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are
open-stuck.
-Faulty vacuum switch.
-The combustion chamber is
dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are
open-stuck.
-Faulty air flow meter.
-The controller
faulty
relay (contacts stuck).
-Reset attempt in shutdown
stage with stove hot in
cooling stage.
-The controller does not
detect the quantity of
combustion air and does not
shut down the stove; it only
excludes the air flow meter
functions.
-Extraordinary
notice.
"direzione e coordinamento della Ferroli spa"
61
-Check pellets in hopper.
-Adjust the pellet flow
-Other reinstatement operations
must be carried out by a service
centre.
-Check the cause of excessive
overheating.
-Reset the safety thermostat by
pressing the reset button.
-Check cleanness of the fume duct
and combustion chamber.
-Check hermetic closing of the
door.
-Check closing of the overpressure
valves.
-Other reinstatement operations
must be carried out by a service
centre.
-Check cleanness of the fume duct
and combustion chamber.
-Check hermetic closing of the
door.
-Check closing of the overpressure
valves.
-Other reinstatement operations
must be carried out by a service
centre.
detects
a
-Reinstatement operations must be
gearmotor
control
carried out by a service centre.
-Alarm reset is possible only after
shutdown.
-Reinstatement operations must be
carried out by a service centre.
- Cleaning - extraordinary
maintenance
maintenance and reinstatement
operations must be carried out by a
authorised service centre.
BEAUTY 13