6.4 Electrical components
7 TROUBLESHOOTING
7.1 Alarm management
Alarms are indicated by an acoustic signal (if activated) and a message on the control panel.
In case of an alarm, shut down the stove, eliminate the cause and restart the stove according to the normal
procedure described in this manual.
The alarms, with causes and cures, which can appear on the control panel are listed below:
Signalling
AL 1
POWER
-The stove does not start.
FAILURE
-Occurs in case of a fume
AL 2
temperature probe fault.
FUME
-The shutdown procedure
PROBE
is activated.
-Occurs if the fume probe
detects a fume
AL 3
temperature above 280°C.
HOT FUMES
-The shutdown procedure
is activated.
-Occurs when the exhaust
AL 4
fan is faulty.
-The shutdown procedure
FAN FAIL
is activated.
-No flame in ignition stage.
AL 5
-The shutdown procedure
NO IGNITION
is activated.
ALARMS - MESSAGES
Fault
-No power during the lighting
stage.
-Faulty probe
-The probe is disconnected
from the board.
-Faulty tangential fan.
-No power to tangential fan.
-Too many pellets.
-The fume fan is blocked.
-Faulty speed control sensor.
-No power to fume fan.
-The pellet hopper is empty.
-The electrical element is
faulty, dirty or not correctly
positioned.
-Pellet load setting incorrect.
60
Key:
1 - Electronic board
2 - Control and safety vacuum switch
3 - Safety thermostat
4 - ON/OFF switch with fuses
5 - Room probe
6 - Fume probe
7 - Electrical element
8 - Air flow meter
9 - Centrifugal fan
10 - Fume extractor
11 - Control panel model EVO
13 - Auger control gearmotor
Possible causes
Cures
-Turn the stove OFF by pressing
the button P4 and repeat the
lighting procedure.
-Other reinstatement operations
must be carried out by a service
centre.
-Reinstatement operations must be
carried out by a service centre.
-Adjust the pellet flow.
-Other reinstatement operations
must be carried out by a service
centre.
-Reinstatement operations must be
carried out by a service centre.
-Check pellets in hopper.
-Check the lighting procedures.
-Other reinstatement operations
must be carried out by a service
centre.
BEAUTY 13