b) Receiver Input
USB TO UART
RXD
SW 1
SW 2
RC
GND
RESET
MODE
UB
U1
GND
5 - 18 VDC
"RC" Mode:
If the 16-channel running light control is to be used for model construction and operated by
remote control, a free receiver output assigned to a rocker switch with central position or a
rotary/sliding control in the transmitter can be used for control.
Practical advice:
For simple switching during the flight or drive, the best switch turned out to be a
rocker switch with central position (on/off//on).
The impulse line of the respective receiver output must be connected to the "RC" input. The
minus line of the receiver output is connected to the ground contact "GND".
"Stand alone" Mode:
If the 16-channel running light control is not to be operated via a remote control, the "RC" input
must be connected to the earth connection "GND". In this case, the four switching outputs (S1
to S4) cannot be used.
28
"RC" Mode
Q1
GND
C11
C10
TXD
LED1
R23
U2
R22
R24
L1
16 - K_Lauflicht_V11
R21
USB TO UART
D3
C7
RXD
RC
GND
RESET
UB
R1
R1
GND
Figure 3
"Stand alone" Mode
GND
C10
TXD
LED1
SW 1
SW 2
R23
MODE
R22
U1
R24
L1
5 - 18 VDC
R21
D3
Q1
C11
C7
U2
R1
R1
16 - K_Lauflicht_V11