Cleaning unit from outside
8.1
CLEANING UNIT FROM OUTSIDE
First of all pull out mains plug from socket.
Danger
Danger of short circuit through penetrating
water! Never spray down the unit with high-
pressure or high-pressure steam cleaners.
Danger
Do not put the high-pressure hose into sol-
vents. Use only a wet cloth to wipe down
the outside of the hose.
Danger
Wipe down unit externally with a cloth which has been im-
mersed in a suitable cleaning agent.
Clean socket and the multifunction switch areas meticulously
also.
8.2
SUCTION FILTER
Clean filters also guarantee the maximum con-
i
veyance quantity, constant spraying pressure
and faultless function of the unit.
•
Unit with suction system
1. Screw off the filter (fig. 13) from suction pipe.
2. Clean or replace the filter. Carry out cleaning with a hard
brush and an appropriate cleaning agent.
•
Unit with upper hopper
1. Release screws with a screwdriver (fig. 14,item 1).
2. Lift (2) and remove filter disk with a screwdriver.
3. Clean or replace the filter disk. Carry out cleaning with a
hard brush and an appropriate cleaning agent.
36
GB
•
•
1. Insert open-ended spanner into the groove of the filter
2. Remove filter housing (1), supporting part (2), centring ring
3. Roll in filter insert (3) (for filter insert with 70 mesh this is not
4. Clean all parts with appropriate cleaning agent. If pressure
5. Remount high-pressure filter.
•
•
•
Intake filter in Airless spray gun
Dismounting (fig. 16)
1. Pull protective guard (1) forward vigorously.
2. Screw grip (2) out of the gun housing. Remove intake filter(3).
3. Intake filter congested or defective – replace.
Mounting
1. Place intake filter (3) with the long cone into the gun
1
2
2. Screw in grip (2) into the gun housing and tighten.
3. Slot in protective guard (1).
8.3
HIGH-PRESSURE FILTER (ACCESSORY)
Switch off unit – set multifunction switch to
Open high-pressure filter and clean filter insert; in addition:
housing (fig. 15, item 1) – screw out filter housing.
(4) and O-ring (5).
necessary) and pull out of supporting part (2).
air is existent – blow through filter insert and supporting
part.
8.4
CLEANING AIRLESS SPRAY GUN
Rinse Airless spray gun with an appropriate cleaning agent.
Clean tip thoroughly with appropriate cleaning agent so that
no coating material residue remains.
Thoroughly clean the outside of the Airless spray gun.
housing.