REMOTE CONTROL
DIP4 - OFF => The REMOTE CONTROL performs
the cyclic command open-stop-
close-stop-open etc.
DIP4 - ON => The REMOTE CONTROL performs:
- the open command, if pressed with
the barrier completely closed
- the close command, if pressed with
the barrier completely opened
- no effect, if pressed during the
barrier opening
- the boom arm re-open, if pressed
while the barrier is closing
AUTOMATIC CLOSING (DIP3 ON)
The Automatic Closing from the complete open
position can be enabled turning ON the DIP3.
The maximum time that can be programmed is 5
minutes (see the Point D).
O
PERATING IN PARK MODE (DIP6 ON)
TO ENTER:
Provided there be a vehicle on the Entry magnetic
loop (see scheme 4), opening can be controlled
by pressing OPEN1, K BUTT or RADIO switch
(OPEN1 performs the boom arm opening only if
the TLC, connected to the Entry Magnetic Loop,
contact is closed).
TO EXIT:
Provided there be a vehicle on the Exit magnetic
loop (see scheme 4), opening can be controlled
by pressing OPEN2, K BUTT, RADIO switch. The
OPEN2 can be connected to the Exit magnetic loop.
If the DIP8 is turned ON, the OPEN2 will perform
the barrier opening regardless the presence of a
vehicle at the Entry.
If the DIP8 is turned OFF, the OPEN2 will perform
the barrier opening if there is no vehicle on the
magnetic sensor connected to the TLC input (TLC
contact opened).
In both the conditions, TO ENTER and TO EXIT,
from the complete boom arm open position:
If the Automatic Closing is enabled (DIP3 ON),
the boom arm will close at the end of the delay time
programmed (see Point C).
If the Automatic Closing is disabled, the boom
arm will remain open until a closing command is
pressed or until the vehicle passes in front of the
photocells, giving an OK CLOSE impulse to the
control board (the OK CLOSE command can be connected to the NO contact of the
photocell receiver).
OPEN2 BUTTON (COM - OPEN2) (ONLY PARK MODE)
If the NORMAL MODE is enabled (DIP6 OFF), the OPEN2 command will be
disabled.
If the PARK MODE is enabled (DIP6 ON), the OPEN2 will perform the boom
arm opening depending on the switch DIP8 position.
If DIP8 is turned ON and PARK MODE is enabled, OPEN2 will perform the
boom arm opening regardless the state of the TLC input.
+
K BUTTON
LED
R=2K2
STOP
CLOSE
+
OPEN 1
LSC
LSO
TIMER
AERIAL
+
+
BUZZER
K BUTTON
LED
R=2K2
-
STOP
CLOSE
+
OPEN 1
12 Vdc max 0,5A for ACCESSORY SUPPLY
12 Vdc max 0,5A for AUTOTEST EDGE
31
31
AERIAL
+
COAX
BUZZER
-
_
_
12 Vdc max 0,5A for ACCESSORY SUPPLY
+
_
12 Vdc max 0,5A for AUTOTEST EDGE
+
COAX
_
+
_
+
If DIP8 is turned OFF and PARK MODE is enabled, OPEN2 will perform the
boom arm opening only if the TLC contact is OPEN (no vehicle at the Entry, see
scheme 4).
OKCLOSE INPUT (COM - OKCLOSE) (ONLY PARK MODE)
If the NORMAL MODE is enabled (DIP6 OFF), the OKCLOSE command will be
disabled.
If the PARK MODE is enabled (DIP6 ON), the OKCLOSE will perform the boom
arm closure after the vehicle transit.
Usually, this command is connected to the Normally Open contact from a
photocell receiver or a magnetic sensor device installed along the boom arm closing
line. The vehicle will engage the contact when it reaches the closing line. The boom
STANDARD OPERATION
DIP 6 OFF
ENTRY
EDGE
NC
NO
COM
S
S
D-
D-
D
+
D
MAGNETIC LOOP
TO EXIT
PARK OPERATION
DIP 6 ON
MAGNETIC LOOP
TO ENTRY
EDGE
NC
NO
COM
S
S
D-
D-
D+
D+
MAGNETIC LOOP
TO EXIT
G
B