I. INSTALLATION INSTRUCTIONS
1. LOCATION
IMPORTANT
1. This icemaker is not intended for outdoor
use. Normal operating ambient temperature
should be within 5°C to 40°C. Water
connection is cold water only. Operation of
the icemaker, for extended periods, outside
of these normal temperature ranges may
affect production capacity.
2. The icemaker should not be located next to
ovens, grills or other high heat producing
equipment.
3. The location should provide a firm and level
foundation for the equipment.
4. Allow 15 cm clearance at rear and sides
for proper air circulation and ease of
maintenance and/or service should they be
required. Allow 60 cm clearance on top to
allow for removal of the auger.
5. This appliance is not suitable for installation
in an area where a water jet could be used
and where dripping is not allowed.
6. D o n o t p l a c e a n y t h i n g o n t o p o f t h e
icemaker or in front of the louver.
2. ELECTRICAL CONNECTIONS
WARNING
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets
t h e n a t i o n a l a n d l o c a l e l e c t r i c a l c o d e
requirements. To prevent possible severe
electrical shock to individuals or extensive
damage to equipment, install a proper earth
wire to the icemaker. Disconnect the main
power supply before any maintenance, repairs
or cleaning is undertaken.
* T h i s a p p l i a n c e r e q u i r e s a s e p a r a t e 2 2 0 -
240VAC, 12A supply. The electrical supply must
be protected by a suitable circuit breaker.
* Usually an electrical permit and services of a
licensed electrician are required.
* If the supply cord is damaged, it must be
replaced by a special cord or assembly available
from the manufacturer or its service agent.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead
of this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
The wire which is coloured Green-and-Yellow
must be connected to the terminal in the plug
which is marked with the letter E or by the symbol
or coloured Green or Green-and-Yellow. The
wire which is coloured Blue must be connected
to the terminal which is marked with the letter N
or coloured Black. The wire which is coloured
Brown must be connected to the terminal which
is marked with the letter L or coloured Red.
* Should the socket outlets in the installation site
not be suitable for the plug supplied with your
product, the plug must be removed (cut off if it is
moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the
power supply cord, it must be disposed of. There
should be no attempt to reuse it. Inserting such a
plug into a socket elsewhere presents a serious
risk of electrical shock.
* The non-rewirable plug must never be used
without a fuse cover being fitted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer's
reference number stamped on the plug.
Supply of replacement fuse covers can be
obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 12A and approved to
BS 1362.
3. WATER SUPPLY AND DRAIN
CONNECTIONS
WARNING
Connect to potable cold water supply only.
Note: A plumbing permit and services of a licensed
plumber may be required in some areas.
3
ENGLISH