English
3. Storing
○ When not in use for an extended period, apply a thin
coat of the lubricant to the steel parts to avoid rust.
○ Do not store the Nailer in a cold weather environment.
Keep the Nailer in a warm area.
○ When not in use, the Nailer should be stored in a
warm and dry place.
Keep out of reach children.
4. WARNING LABEL
Do not use the Nailer with missing or damaged
WARNING LABEL.
A new WARNING LABEL is available from a
metabo HPT authorized service center.
5. Maintenance chart (page 20)
6. Operator troubleshooting (pages 21)
7. Service parts list
A: Item No.
B: Code No.
C: No. Used
D: Remarks
Maintenance chart
ACTION
Drain air line fi lter daily.
Keep lubricator fi lled.
Clean fi lter element and blow air
through fi lter in direction opposite to
normal fl ow daily.
Clean magazine and feeder
mechanism.
Keep push lever working properly.
Lubricate the Nailer after nailing.
Drain air compressor daily.
20
CAUTION
● Repair, modifi cation and inspection of metabo HPT
MODIFICATIONS
metabo HPT Power Tools are constantly being improved
and modifi ed to incorporate the latest technological
advancements.
Accordingly, some parts (i.e. code numbers and/or
design) may be changed without prior notice.
SERVICE AND REPAIRS
Warning
Label
All quality Nailers will eventually require servicing or
replacement of parts because of wear from normal use.
NOTE
WHY
Prevent accumulation of moisture
and dirt.
Keep the Nailer lubricated.
Prevent clogging of fi lter with dirt.
Prevent a jam.
Promote operator safety and effi cient
Nailer operation.
Extend the Nailer life.
Keep the Nailer operated properly.
Power Tools must be carried out by an metabo HPT
Authorized Service Center.
This Parts List will be helpful if presented with the
tool to the metabo HPT Authorized Service Center
when requesting repair or other maintenance. In
the operation and maintenance of power tools,
the safety regulations and standards prescribed
in each country must be observed.
WARNING
● Only service personnel trained by metabo HPT,
distributor or employer shall repair the Nailer.
● Use only parts supplied or recommended by
metabo HPT for repair.
Specifi cations are subject to change without any
obligation on the part of metabo HPT.
Open manual petcock.
Fill with metabo HPT pneumatic tool
lubricant.
Follow manufacturer's instructions.
Blow clean daily.
Blow clean daily.
Supply 5 – 10 drops of lubricant into
the Nailer.
Open petcock on air compressor
tank.
HOW