English
The SINGLE SEQUENTIAL ACTUATION MECHANISM
may reduce the possibility of bodily injury to you or others
in the work area compared to the CONTACT ACTUATION
MECHANISM. This is because it is less likely to drive
an unwanted nail if you keep the trigger pulled and
accidentally bump the push lever against yourself or
others.
The SINGLE SEQUENTIAL ACTUATION MECHANISM
may also reduce the speed of operation compared
to the CONTACT ACTUATION MECHANISM. The
SINGLE SEQUENTIAL ACTUATION MECHANISM is
recommended to inexperienced users.
NOTE
● If all warnings and instructions are followed, safe
operation is possible with two systems: SINGLE
SEQUENTIAL ACTUATION MECHANISM and
CONTACT ACTUATION MECHANISM.
● Always handle nails and package carefully. If nails
are dropped, collating wire may be broken.
● After nailing:
1) disconnect air hose from the Nailer;
2) remove all nails from the Nailer;
3) supply 5 – 10 drops of metabo HPT pneumatic
tool lubricant into the air plug on the Nailer; and
4) open the petcock on the air compressor tank to
drain any moisture.
ADJUSTING THE NAILING DEPTH
To assure that each nail penetrates to the same depth, be
sure that:
1) the air pressure to the Nailer remains constant
(requlator is installed and working properly), and
2) the Nailer is always held fi rmly against the workpiece.
If nails are driven too deep or shallow into the workpiece,
adjust the nailing in the following order.
1 DISCONNECT AIR HOSE FROM NAILER.
2 If nails are driven too deep, turn the adjuster to the
shallow side.
Adjustments are in half-turn increments.
18
Adjuster
15
Disconnect
air hose
Turn Adjuster
2
Too Deep
If nails are driven too shallow, turn the adjuster to the
deep side.
2
Too Shallow
3 Stop turning the adjuster when a suitable position is
reached for a nailing test.
4 Connect the air hose.
ALWAYS WEAR EYE PROTECTOR.
Perform a nailing test.
5 DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.
USING THE NOSE CAP
● Disconnect the air hose from the nailer
before attaching or removing the nose cap.
If you like to protect the surface of workpiece against
scratches or markings made by the push lever, attach the
accessory nose cap to the push lever.
1 DISCONNECT AIR HOSE FROM NAILER.
2 Put the nose cap to the toe of the push lever.
NOTE:
● The nose cap may reduce nailing depth due to its
thickness. Re-adjustment of nailing depth is required.
Do not connect
1
air hose
Protrusion
(Inward)
Flush
Turn Adjuster
Flush
WARNING
Hole
Nose
Push Lever
Nose Cap