Concrete and Anchoring:
If you are installing a seismic lift, consult with your
structural engineer and manufacturer's representative for
concrete and anchoring requirements (varies by location).
Fig. 4 and the below table apply to non-seismic lifts only.
Anchor:
Min
Min Edge
Concrete
Distance
Thickness
Hilti Kwik
4-1/4"
3-3/8"
Bolt III (3/4" x
(108mm)
(86mm)
5-1/2")
Hilti HY200
6-7/16"
1-3/4"
(with HAS
(164mm)
(45mm)
threaded rod)
Hilti HY200
5-1/4"
3" (77mm) 3-1/2" (89mm) 100 (149Nm) / less
(with HAS
(134mm)
threaded rod)
"Automotive Lifts - Safety Requirements for Construction, Testing, and Validation" ANSI/ALI ALCTV-2011,
and the lift owner is responsible for all charges related to any additional anchoring requirements as
specified by local codes. Contact customer service for further information at: 800.640.5438
Drill holes using 3/4" carbide
tipped masonry drill bit per
ANSI B212.15-1994 (R2000).
Construction dust collected
per OSHA 29 CFR 1926.1153.
7-10K 2-Post Lift Anchor Installation Reference Guide
Min Anchor
Installation Anchor
Embedment
Torque ft-lbs
3-1/4" (83mm) 110
(149Nm)
4-1/2"
100 (149Nm) / less
(115mm)
than 3-3/4" (95mm)
edge distance use
Torque Value of 30
ft-lbs (41Nm)
than 3-3/4" (95mm)
edge distance use
Torque Value of 30
ft-lbs (41Nm)
*The supplied concrete fasteners meet the criteria of the American National Standard
Run nut down just below impact
section of bolt. Drive anchor
into hole until nut and washer
contact base.
Min Concrete PSI
Concrete pad
Strength - For All
Size If Concrete
Standards
Does Not Meet
Requirements
3000
4'x4'x6"
(20684 kPa)
(1219 x 1219 x
152mm)
3000
4'x4'x6"
(20684 kPa)
(1219 x 1219 x
152mm)
3000
4'x4'x6"
(20684 kPa)
(1219 x 1219 x
152mm)
5
Tighten nut with Torque
wrench to 110 ft.-lbs
.
(149 Nm).
Fig. 4
Maintenance
SEISMIC
Torque
Values
65 ft-lbs
Varies by
(88Nm)
location consult
with your
N/A
structural engineer
and manufacturer's
representative.
N/A