Signal Output: Canopen - HYDAC ELECTRONIC CANopen HAT 3800 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

HAT 3800 CANopen

6.2 Signal output: CANopen

Service Data Object (SDO)
Using the SDOs, other network nodes can read from or write to the Object
Dictionary of the angle sensor.
Process Data Object (PDO)
Via the PDOs the measured values (position values) of the angle sensor are
provided to other network nodes.
Synchronisation Object (SYNC)
SYNC objects are used to implement a synchronous data transmission. The angle
sensor provides the functionality of a SYNC consumer.
Emergency Object (EMCY)
EMCY objects are sent when an error occurs. EMCY objects contain an
Emergency Error Code and the contents of an Error register.
The Object Dictionary
With CANopen, all the device's data (setting parameters and measured values) is
filed in an Object Dictionary under a specified Index. The angle sensor supports
the records of DS 301, of the encoder profile DS 406 and of the NMT and LSS
services.
NMT Services
NMT objects are used to start, stop or reset devices. CANopen differentiates
between the following functionalities:
1. NMT Master: controls other nodes.
2. NMT Slave: is controlled by a Master.
LSS Services
The LSS services and protocols (CiA DS-305) are used to inquire or to configure
different parameter settings of the Data Link Layers and the Application Layers of a
LSS slave by a LSS master as for example the setting of Baud rate and Node ID.
EDS File
The EDS file represents the electronic description of the Object Dictionary.
Edition: 2021-02-18
HYDAC ELECTRONIC GMBH
13
E
Part No.: 669968

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hat 3800 canopen

Table des Matières