WARNINGS for programming:
• Always read the procedure first and then perform the operations in the
correct sequence.
• In this manual the transmitter keys are identified by means of numbers.
To check the correspondence of numbers and the transmitter keys see
fig. 42.
42
T1
T3
STEP 9
9.1 – MEMORISING THE DEVICES CONNECTED BY
MEANS OF "BUS" CABLE AND THE LEAF "CLOSING"
AND "OPENING" LIMIT POSITIONS
After ensuring correct operation of the control unit, it must be pro-
grammed as described in the sequence below:
Note – During this procedure, the user can exit the process at any time
(without saving the operations performed) by pressing "P1" once on the
control unit (fig. 41). In particular, from point 07 onwards, the user can
also exit the procedure by activation of a safety device (photocell or oth-
er...).
01. (on the gate)
Release the gearmotor by means of the special release key (see
chapter "Manually releasing or locking the gearmotor" in the sec-
tion TECHNICAL DOCUMENTATION) and manually move the gate
leaf to mid-travel. Then lock the gearmotor again.
02. (on the control unit)
Press and hold the key "P1" for at least 5 seconds; the green and red
Leds illuminate. Then release the key when the green led turns off (the
red led remains lit through to the end of the procedure) and proceed
as follows:
03. (on safety Photocells)
Note – The time available for this check is unlimited.
Check correct operation of these types of photocells, ensuring that
the relative Led flashes slowly. Otherwise if it is lit or off, correct align-
ment between the photocells attempting to obtain a flashing frequen-
cy that is slow as possible (the slower the flashing speed, the better
the photocell alignment).
• slow flashing light = correct photocell alignment;
• light permanently lit = incorrect alignment (revise photocell align-
ment);
• light off = photocells installed incorrectly (check "Bus" connection of
photocells).
04. (on control Photocells)
Activate this type of photocell (if fitted on the system), interrupting the
beam once only. Successful learning is confirmed by the flashing light
(1 flash) and the keypad (1 beep), if fitted on the system.
05. (on the keypads)
Activate the keypads (if fitted on the system) by pressing any key on
each one as required.
Successful learning is confirmed by 2 beeps at short intervals, emitted
by the keypad and 1 flash of the flashing light, if fitted on the system.
PROGRAMMING THE AUTOMATION
06. (on the control unit)
Press and hold the key "P1" for at least 5 seconds; the green led illu-
minates and release the key when the green Led turns off.
07. (on the gate)
At this point the ate leaf moves independently to reach the Opening
limit position.
Note – If fine adjustments to the travel limit position are required, use
the adjustment screw inside the gearmotor as follows (fig. 43):
Locate the screw with the arrow corresponding to the direction in
which the leaf is moved, and adjust until the leaf reaches the required
T2
limit position.
43
T4
08. (on the control unit)
Press and hold the key "P1" for at least 5 seconds; the green led illu-
minates and release the key when the green Led turns off.
09. (on the gate)
At this point the gate leaf moves independently to reach the Closing
limit position.
Note – If fine adjustments to the travel limit position are required, use
the adjustment screw inside the gearmotor as follows (fig. 44):
Locate the screw with the arrow corresponding to the direction in
which the leaf is moved, and adjust until the leaf reaches the
requiredlimit position.
44
10. (on the control unit)
Press and hold the key "P1" for at least 5 seconds; the green led illu-
minates and release the key when the green Led turns off.
At this point the control unit independently starts 2 manoeuvres also
indicated by the flashing light:
1 - Leaf opening.
2 - Leaf closure.
At the end of the last manoeuvre, the red led turns off (= procedure
completed) and then resumes flashing at regular intervals.
If the results of these checks do not conform with specifications, stop
the procedure immediately by pressing P1 on the control unit once.
Then repeat the entire procedure 9.1 and check correct operation of
the photocells, or modify settings of the "Leaf sensitivity to obsta-
cles" as described in Chapter 10 "Automation operation adjustment"
and if necessary check electrical connections.