GRMF SERIES GAS FRYERS
BOIL OUT PROCEDURE:
Use the Boil Out By-Pass™ drain extension allowing the boil out
solution to exit the fry tank without using the filtering system. Do
NOT allow water to run through the motor / pump. Drain the boil
out solution into a bucket or place a high temperature rated water
hose on the end of the drain extension allowing the other end to
flow into a floor drain. In Fig. 8 the arrow is pointing to the drain
extension. It is threaded into the top coupling of the oil drain tube.
Drain extension needs to be only hand tightened.
Boil Out By-Pass™ Extension Tube
Standard Hose End (Smaller Thread Side)
THERMAL OVERLOAD PROTECTION BUTTON:
The motor/pump supplied with the filtering system
has a thermal overload protection circuit that senses
when excess heat occurs due to filtering for long
periods of time or under heavy load prior to
discarding debris buildup. If the thermal overload
protection is tripped, wait 5 minutes and then reset
the motor by pushing in the red button. The arrow in
Figure 9 shows the location of the reset button;
located on the front of the motor / pump facing
towards you.
VULCAN-HART
Drain Tube End (Larger Size Threads)
-23-
Fig. 8
Fig. 9