Safety Instructions

Do not grab the feeder cable, plunge the pump, lift or
carry it while it is connected to the grid!
Unplug the device prior to submersion, upon termi-
nation of operation, in the course of defect removal
and prior to performing maintenance procedures.
If the pump is in operation, neither people nor animals
can be present or plunged in the pumped liquid (e.g.
pools, cellars, etc.).
The temperature of the drained liquid must not
exceed +35 °C.
The pump must not in any case run without fillings.
Do not leave the pump unattended while in operati-
on in order to prevent subsequent damages caused
by eventual malfunctions. Make sure to disconnect
the device from the grid if you do not plan on using it.
If the pump is used in ponds, wells, etc. and appropri-
ate pumping stations, standards valid for pumps in
the given country must unconditionally be observed.
The user is responsible to third parties if pump (dum-
ping stations, etc.) is used.
Check the cable and/or socket for damages before
the appliance putting into operation.

Mains Connection

Operation is only allowed with a safety
switch against stray current (RCD max. stray
current of 30mA).
WARNING! Electric shock! There is a risk of an
injury caused by electric shock!
Before putting into operation, a qualified electrician
must check whether electric safety measures required
are in place. Any national regulations in this regard
must be complied with.
Electric connection to a socket.
Check the voltage. Technical data given on the type
label must correspond with electric network voltage.
It is necessary to make sure the connecting socket
was not near water and humidity and the plug was
protected against humidity.
Only use splash proof extension cables approved for
outdoor purposes.
Protect the feeder cable from excessive temperatures,
oil and sharp edges.
Maintenance
Unplug the machine before any work on it.
Before using the appliance, perform a visual inspec-
tion at all times to make sure the power cord and the
plug, in particular, are not damaged on the charger.
The appliance must not be used if damaged or safety
equipment is defective. Replace any worn-out and
damaged parts.
If the supply cord of this power tool is damaged,
it cannot be replaced, and the power tool shall be
scrapped.
Repairs and works specified in these Instructions may
only be performed by qualified authorised staff.
Use only original accessories and original spare parts.
Only a regularly maintained and treated appliance
can serve as a satisfactory aid. Insufficient mainte-
nance and care can lead to unforeseen accidents and
injuries.
To ensure long service life of the pump seal we
recommend rinsing the pump with clean water in
regular intervals.
At winter storing, it is necessary to make sure there is
no water in the appliance as the frost could damage
the appliance. Prior to transportation, it is necessary
to unplug the pump from the grid! The device has to
be completely emptied and stored with frost-proof
protection. Adhesion of mechanical seals can be
prevented if you rinse the pump with appropriate oil
(for example, with vegetable oil).
If necessary, a list of spare parts can be found at
www.guede.com.
Guarantee
Warranty period of 12 months applies to commercial
use and 24 months applies to private use and com-
mences on the day of purchase of the device.
The guarantee solely covers inadequacies caused
by material defect or manufacturing defect. Original
payment voucher with the sales date needs to be sub-
mitted for any claim in the guarantee period.
The guarantee does not cover any unauthorised
use such as appliance overloading, use of violence,
damage as a result of any unauthorised interference
or caused by foreign items. Failing to follow the ope-
rating and assembly instructions and common wear
are also not included in the guarantee.
GÜDE cannot be held responsible for damages
incurred in consequence of unqualified installation or
unskilled handling of the pump.
The device has to be checked on a regular basis to
ensure perfect functioning.
Let us refer to the fact we do not assume any respon-
sibility – according to standards in force – for damage
eventually caused by our appliances in the below-
mentioned cases:
Unprofessional repairs executed by unauthorised
service centres;
• Use in conflict with the designed purpose, or
failure to observe the use as designed;
• Pump overload with a continuous run;
• Damage as a result of icing or any other fault
caused by climatic influences;
Identical regulations apply for accessory parts.
To prevent damage (such as flooded rooms, etc.) as a
result of faulty pump operation (failure or fault) the ow-
ner (user) is obliged to take reasonable safety measures

Publicité