Special functions
Exit from the USER menu
Open/Close the gas valve in order to purge the torch, check
the gas bottle and pressure reducer. Press "A" to Open/Close
the gas. Exiting the USER menu will close the gas anyway.
Calibration of gas flow at 10 and 20 litres by means of
flowmeter (81010000).
Submenu for MMA procediment
Exit from submenu
Value of Hot Start
Value of Arc Power
Submenu for PLASMA procediment
Exit from submenu
Pilot Arc Active
Controls the activation of Pilot Arc during welding.
0: Arc always OFF
1: Arc ON only during slope-up and slope-down
2: Arc always ON (default)
External Cooling Mode
Selects the Internal or External Cooling unit
0: INTERNAL cooler
1: EXTERNAL cooler (default)
Submenu for wire feeder
Exit from submenu
Active control of CWF
0 = no CWF (default)
1 = at least one CWF
Submenu containing different options
Exit from submenu
Programs LOCK
0 = unlocked (default setting)
1 = locked P3 to P64
2 = locked P1 to P64
Panel LOCK
0 = unlocked (default setting)
1 = locked, except "pilot arc ON/OFF"
2 = Completely locked
2-times option for torch trigger
0: return to welding current by step. (default)
1: return to welding current by slope up
Press / Release
Press / Release
4-times option for torch trigger
Permit to define 6 different ways to control the torch
trigger when the machine is set as 4Times stroke
(Lift or HF). For detailed description of different
behaviours see the following diagrams. Select a value
in the range 0...5 (1=default setting).
Press / Release
Press / Release
Press / Release
Keep
start current
Press / Release
Keep
start current
Press / Release
Keep
start current
Press / Release
Note: The start current is disabled in
15
By SlopeUP
Stop when key is released
Stop when key is released
Stop when key is released
Stop when key is released
if slope-up period is set at 0
5
0
By STEP
1
Keep
final current
0
Stop when
slope completed
1
Stop when
slope completed
2
3
Stop when
slope completed
4
Keep
final current
5
3
,
4
and