5.1.3. ELECTRICAL CONNECTIONS

2
1
FAACLAMP
MINILAMP
J4
7 8 9
J3
230V~
max 25W
J1
1
2
3
230V~
(+6% -10%)
50Hz
230V~
max 25W
C
8µF
5
4
3
2
1
10 11 12 13 14 15 16 17 18 19
J5
DS1
ON
TR1
-
+
DL1
TR2
-
+
TR3
DL2
-
+
550 MP
J2
4 5 6
C
8µF
M
6
4
5
GROUND
550 SLAVE
M
5.2.
DESCRIPTION
5.2.1. TERMINAL BLOCK J1 (high voltage)
Terminal block for 230V~ 50Hz power supply (F= Phase N=Neutral).
Connect the electrical system earth and the operator earth
cable to the "Ground" terminal.
5.2.2. TERMINAL BLOCK J2 (high voltage)
230V~ terminal block for connecting the electric motor.
B
LACK CABLE AND BROWN CABLE
B
= electric motor common (COM)
LUE CABLE
The surge capacitor must be connected in parallel with the
phases.
5.2.3. TERMINAL BLOCK J3 (high voltage)
230V~ terminal block for connecting:
• Flashing light (FLASH) max. 60W.
• Courtesy light of 550 Slave (EXT LAMP) or alternatively an
external courtesy light max. 100W.
5.2.4. TERMINAL BLOCK J4 (low voltage)
FCC= Closure limit switch contact (N.C.)
The closure limit switch (optional) consists of a microswitch
which is activated by the cam when the door reaches
the closed position and stops movement after 2 seconds.
FCA= Opening limit switch contact (N.C.)
The opening limit switch (optional) consists of a
microswitch which is activated by the cam when the
door reaches the open position and stops movement
immediately.
Ü If limit switch devices are not used, jumper FCC and FCA with
the common inputs.
= Common inputs/Accessories power supply negative
= Accessories power supply positive 24Vdc (+)
The max. accessories load is 500mA.
To calculate absorption values, refer to the instructions
for the individual accessories.
FSW= Closing safeties contact (N.C.)
The term "safeties" refers to any device (photocells,
safety edges, etc.) with an N.C. contact that reverses
the closing movement of the door when it detects an
obstacle within the area it protects.
These devices have no effect during opening.
If the safeties are engaged when the door is closed,
stopped or open, they prevent it from moving.
To install a number of safety devices, connect the N.C.
contacts in series.
Ü If safety devices are not connected, jumper FSW with the
common inputs.
STOP= STOP command (N.C.)
Any device (e.g.button) which stops the door movement
by opening a contact.
To install a number of stop devices, connect the N.C.
contacts in series.
Ü If Stop devices are not connected, jumper the STOP and
common inputs.
OPEN=OPEN command (N.O.)
Any device (button, detector, etc.) which activates
door opening (or closing) by closing a contact.
To install a number of Open devices, connect the N.O.
contacts in parallel.
5.2.5. CONNECTOR J5 (low voltage)
Connector J5 is used for quick connection of MINIDEC, DECODER
and RP RECEIVER cards.
Fit the accessories cards so that their component side faces the
inside of the 550MP card.
Disconnect power before engaging or removing.
Fig. 15
14
ENGLISH
= electric motor phases (OP/CL)