Installation instructions, only for experts

5.3. Connecting the light

1. Guide the light cable through the cable bushing c into the connection area
for 230 V/400 V g.
2. Connect the light cable to the terminal strip e in accordance with the con-
nection diagram. Observe the operating instructions for the respective device.

5.4. Connecting the fan (optional)

1. Guide the fan cable through the cable bushing c into the connection area
for 230 V/400 V g.
2. Connect the fan cable to the terminal strip e in accordance with the connec-
tion diagram. Observe the operating instructions for the respective device.

5.5. Connecting the additional output (optional)

The additional output can, for example, be used for an infrared lamp or infrared
heat plates.
WARnInG!
Risk of fi re
The additional output has no excess temperature fuse. For this reason
only intrinsically safe devices should be used on the additional output.
● If infrared heaters are connected to the additional output, these must
have an excess temperature fuse.
● If infrared heat plates are connected to the additional output, the foil
sensor P-ISX-FF must be used and activated when starting up the
sauna for the fi rst time (see 8.6. Activating/deactivating the foil
sensor on page 31).
1. Guide the connection cable for the additional device through the cable bush-
ing 8 into the connection area for 230 V/400 V g.
2. Connect the power supply cables to the terminal strip d in accordance
with the connection diagram. Observe the operating instructions and safety
instructions for the respective device.