Installation instructions, only for experts
4.3. Connecting the safety shut-off
Observe the following points when connecting the power to the safety shut-off:
● Installation may only be performed by a qualified electrician or similarly quali-
fied person.
Please note that in the event of a guarantee claim, a copy of the invoice
issued by the electrician performing the work must be presented.
● The electrical wiring may only be laid when the power has been disconnected.
● Please observe Fig. 3 on page 11, the Connection diagram on page 14
and the operating instructions for your sauna control unit.
Sauna control units with connection terminals for safety shut-offs
(e.g. Pro-B2, Pro-B3, Pro-C2, Pro-C3, JUST-105D-CO, JUST-105W-CO, JUST-
105D-FI, JUST-105W-FI)
4. Connect the two wires of the right part of the safety shut-off to the terminals
labelled "NC1".
5. Connect the two wires of the left part of the safety shut-off to the terminals
labelled "NC2".
6. Connect the two wires of the silicone cable included to the two terminals
"STRG".
7. Guide the silicone cable to the sauna control unit and connect the two wires
to the terminals labelled "OSG".
WORLD OF WELLNESS
p. 10/18